Mounting
page 19
With threaded connection, the antenna end should protrude at least
5 mm (0.2 in) out of the nozzle.
ca. 5 mm
Fig. 13: Thread mounting
If the reflective properties of the medium are good, you can mount
NivoRadar 7100 on sockets longer than the antenna. The socket
end should be smooth and burr-free, if possible also rounded.
You will find recommended values for socket heights in the following
illustration or the table. The values come from typical applications.
Deviating from the proposed dimensions, also longer sockets are
possible, however the local conditions must be taken into account.
d
h
Fig. 14: Socket mounting
Socket diameter d
Socket length h
40 mm
1½"
≤ 150 mm
≤ 5.9 in
50 mm
2"
≤ 200 mm
≤ 7.9 in
80 mm
3"
≤ 300 mm
≤ 11.8 in
100 mm
4"
≤ 400 mm
≤ 15.8 in
150 mm
6"
≤ 600 mm
≤ 23.6 in
Note:
When mounting on longer nozzles, we recommend carrying out a
false signal suppression (see chapter " Parameter adjustment").
The mounting location of the radar sensor should be a place where
no other equipment or fixtures cross the path of the radar signals.
Vessel installations, such as e.g. ladders, limit switches, heating
spirals, struts, etc., can cause false echoes and impair the useful
echo. Make sure when planning your measuring point that the radar
sensor has a " clear view" to the measured product.
In case of existing vessel installations, a false signal suppression
should be carried out during setup.
If large vessel installations such as struts or supports cause false
echoes, these can be attenuated through supplementary measures.
Threaded socket und
socket piece