1.1. BASIC SAFETY INSTRUCTIONS

To minimise the risk of injury, the following basic safety precautions should be observed 

with each use of the Product: 

Do not remove the sticker on the front of the unit until the Product is commissioned by 

a qualified installer. 

Do not put any object close to the surface of the Product.

Do not put plastic or glass in front of the Product. It does not allow UV to pass through.

Make sure the Product has an unobstructed path towards the area to be disinfected.

Do not use flammable substances near the lamp module.

This is an electronic device. Do not use flammable or combustible gases or liquids, such as 

oxygen, hydrogen, or chemicals, near a lamp module. Failure to obey may result in fire or 

explosion.

Do not turn on any Product with a broken front glass. 

If the front glass is broken, disconnect Product immediately and contact an authorised 

installer. 

Do not disassemble or modify the lamp module.

Disassembly or modification may result in fire, electric shock, or injury.

Turn off the electrical power during lamp module maintenance.

Do not remove any safety labelling or parts.

Do not touch the lamp module during operation.

Otherwise, it may result in fire, electric shock, or injury.

Ground the device or metal parts of the housing that are close to the lamp module.

Otherwise, it may result in fire, electric shock, or injury.

Do not use the unit for purposes other than disinfection.

The unit is designed for disinfection. Using it for any other purpose may result in unexpect

-

ed accidents.

Содержание UV222

Страница 1: ...Filtered Far UV C Technical Installation Manual Industrial...

Страница 2: ...UV LIGHT DO NOT USE THE PRODUCT BEFORE CAREFULLY READING THIS MANUAL ALWAYS KEEP THIS MANUAL WITH THE PRODUCT AND CONSULT IT REGULARLY ATTENTION Lumi re UV mise par cet appareil vitez de regarder dire...

Страница 3: ...u suspect that the Product is damaged or detect a potential or actual danger when using the Product immediately discontinue use of the Product and contact your supplier of the Product Contents 1 USING...

Страница 4: ...as oxygen hydrogen or chemicals near a lamp module Failure to obey may result in fire or explosion Do not turn on any Product with a broken front glass If the front glass is broken disconnect Product...

Страница 5: ...acting on behalf of another person your employer that person must instruct you in accordance with the Manual and ensure that all instructions set out herein are complied with Do not use the Product if...

Страница 6: ...ility are void if any modifica tions are done to the Product 4 GENERAL CHARACTERISTICS AND TECHNICAL SPECIFICATIONS UV222 Industrial has an IP66 rating and is designed to emit Far UV C radiation with...

Страница 7: ...7 5 CONSTRUCTION 100 mm 3 9 in 110 mm 4 3 in R 3 5 mm 0 1 in 53 mm 2 1 in 60 mm 2 4 in 113 mm 4 4 in 300 mm 11 8 in 142 mm 5 6 in 168 mm 6 6 in...

Страница 8: ...umidity remains within the Product s specifications The Product functions ideally in a temperature range from 10 to 50 C 14 to 122 F Select a Product mounting location that is close to surface area th...

Страница 9: ...surface must be strong enough to hold 4 times the weight of the unit 100 mm 3 9 in 110 mm 4 3 in R 3 5 mm 0 1 in 53 mm 2 1 in 60 mm 2 4 in 113 mm 4 4 in 300 mm 11 8 in 142 mm 5 6 in 168 mm 6 6 in Tak...

Страница 10: ...lead Standard wiring Phase Hot brown black Neutral Cold blue white Earth green yellow green How to wire the Product 1 Remove all screws and take off the back plate A 2 Unscrew 2x ph1 cable blockage B...

Страница 11: ...nning of this installation 6 6 Setting up the Product The installer will need a Microsoft Windows computer with the UV Medico application installed Contact your distributor to get access to the latest...

Страница 12: ...stallation Manual 12 1 If the Product was already installed you can recover its settings by pressing Get All settings will then be shown in the application A 2 Check if firmware version is the latest...

Страница 13: ...ty cycle of the room where the Product is installed On time Time from which the room will be occupied by people E Off time Time from which the room will not be occupied F C Select the correct firmware...

Страница 14: ...e and post cleaning cycle if desired B The unit will then light up before and after the duty cycle 7 Change the intensity of the LED signal to the desired output C 8 Select mode D NOTE The current mod...

Страница 15: ...0 Press Set to upload the settings into the Product F F E Once this information is saved and programmed into the unit it is ready to test start up The unit will calculate the radiation automatically t...

Страница 16: ...ence on the risks of exposure the installer needs to be contacted so the Product is repro grammed 11 Testing the Product Right click on the photo of the Product A and a pop up of the test mode will sh...

Страница 17: ...continuous Out of cycle Flashing red Object too close Flashing magenta Pre disinfection after disinfection per seen movement Red blue green loop Recommended change of Far UV C light source If the LED...

Страница 18: ...t Does not hold settings Replace battery If the failure is unsolved or recurring please return the unit to an official UV Medico dealer service centre for repair or replacement see point 10 REPAIRS 8...

Страница 19: ...drawings The information given in this manual has been collected for the general convenience of our customers It has been based on general data pertaining to construction material properties and worki...

Страница 20: ...UV Medico A S S ren Frichs Vej 40E 8230 byh j Denmark 45 20 90 71 30 info uvmedico com www uvmedico com Version 06 2022...