background image

11

6.5. Understanding the unit’s operation

The maximum permissible UV-C exposure shall not exceed the ACGIH TLV and NIOSH REL 

of 22.0 mJ/cm² for an 8 h day, 40 h work week exposure to UV radiation at 222 nm.

(UV Medico A/S expects positive changes into the ACGIH that will result in a higher expo

-

sure than allowed at this moment. If this changes, UV Medico A/S will update the software 

of the unit to align with the new threshold of exposure). 

To achieve the correct radiation within these limits, following information will be 

 

programmed into the Product before the beginning of this installation.

6.6. Setting up the Product

The installer will need a Microsoft Windows computer with the UV Medico application 

installed. Contact your distributor to get access to the latest software and firmware for the 

Product. 

To launch the app, go to the installed folder and open the file:

UV Medico Configuration App.exe

The app includes two different set up modes: simple and advanced. 

For the simple mode, follow the instructions that will appear on the screen. 

For the advanced mode, see below:

Remove the cap on the bottom of the unit 
to access the USB-C connection 

D

 and 

connect to a computer with a USB cable. 

When you connect your computer to the 

unit, it will show up automatically on the 

application.

Once the app is launched, follow the next 

steps:

D

Содержание UV222

Страница 1: ...Filtered Far UV C Technical Installation Manual Industrial...

Страница 2: ...UV LIGHT DO NOT USE THE PRODUCT BEFORE CAREFULLY READING THIS MANUAL ALWAYS KEEP THIS MANUAL WITH THE PRODUCT AND CONSULT IT REGULARLY ATTENTION Lumi re UV mise par cet appareil vitez de regarder dire...

Страница 3: ...u suspect that the Product is damaged or detect a potential or actual danger when using the Product immediately discontinue use of the Product and contact your supplier of the Product Contents 1 USING...

Страница 4: ...as oxygen hydrogen or chemicals near a lamp module Failure to obey may result in fire or explosion Do not turn on any Product with a broken front glass If the front glass is broken disconnect Product...

Страница 5: ...acting on behalf of another person your employer that person must instruct you in accordance with the Manual and ensure that all instructions set out herein are complied with Do not use the Product if...

Страница 6: ...ility are void if any modifica tions are done to the Product 4 GENERAL CHARACTERISTICS AND TECHNICAL SPECIFICATIONS UV222 Industrial has an IP66 rating and is designed to emit Far UV C radiation with...

Страница 7: ...7 5 CONSTRUCTION 100 mm 3 9 in 110 mm 4 3 in R 3 5 mm 0 1 in 53 mm 2 1 in 60 mm 2 4 in 113 mm 4 4 in 300 mm 11 8 in 142 mm 5 6 in 168 mm 6 6 in...

Страница 8: ...umidity remains within the Product s specifications The Product functions ideally in a temperature range from 10 to 50 C 14 to 122 F Select a Product mounting location that is close to surface area th...

Страница 9: ...surface must be strong enough to hold 4 times the weight of the unit 100 mm 3 9 in 110 mm 4 3 in R 3 5 mm 0 1 in 53 mm 2 1 in 60 mm 2 4 in 113 mm 4 4 in 300 mm 11 8 in 142 mm 5 6 in 168 mm 6 6 in Tak...

Страница 10: ...lead Standard wiring Phase Hot brown black Neutral Cold blue white Earth green yellow green How to wire the Product 1 Remove all screws and take off the back plate A 2 Unscrew 2x ph1 cable blockage B...

Страница 11: ...nning of this installation 6 6 Setting up the Product The installer will need a Microsoft Windows computer with the UV Medico application installed Contact your distributor to get access to the latest...

Страница 12: ...stallation Manual 12 1 If the Product was already installed you can recover its settings by pressing Get All settings will then be shown in the application A 2 Check if firmware version is the latest...

Страница 13: ...ty cycle of the room where the Product is installed On time Time from which the room will be occupied by people E Off time Time from which the room will not be occupied F C Select the correct firmware...

Страница 14: ...e and post cleaning cycle if desired B The unit will then light up before and after the duty cycle 7 Change the intensity of the LED signal to the desired output C 8 Select mode D NOTE The current mod...

Страница 15: ...0 Press Set to upload the settings into the Product F F E Once this information is saved and programmed into the unit it is ready to test start up The unit will calculate the radiation automatically t...

Страница 16: ...ence on the risks of exposure the installer needs to be contacted so the Product is repro grammed 11 Testing the Product Right click on the photo of the Product A and a pop up of the test mode will sh...

Страница 17: ...continuous Out of cycle Flashing red Object too close Flashing magenta Pre disinfection after disinfection per seen movement Red blue green loop Recommended change of Far UV C light source If the LED...

Страница 18: ...t Does not hold settings Replace battery If the failure is unsolved or recurring please return the unit to an official UV Medico dealer service centre for repair or replacement see point 10 REPAIRS 8...

Страница 19: ...drawings The information given in this manual has been collected for the general convenience of our customers It has been based on general data pertaining to construction material properties and worki...

Страница 20: ...UV Medico A S S ren Frichs Vej 40E 8230 byh j Denmark 45 20 90 71 30 info uvmedico com www uvmedico com Version 06 2022...

Отзывы: