background image

6

CARE AND MAINTENANCE

CLEANING

CLEANING THE HEATING ELEMENT:

To clean the heating element, loosen (but do not remove) the four Phillips head screws located behind the louvers 

in the corners of the louver housing on both sides, lift up, and pull out (see Figure 8).  This provides access to the 

heating element. Remove dust or lint with a soft brush or a vacuum cleaner. Replace the louver housing and tighten 

the Phillips head screws.

Any other service should be performed by an authorized service representative.

CLEANING THE FAN AND MOTOR:

Remove the protective grille from the rear of the heater. This provides access to the fan and motor. Wipe off the fan 

and the motor with a soft cloth or brush. The fan motor does not require lubrication. Replace protective grille  (see 

Figure 9).

IMPORTANT DIGITAL DISPLAY STATUS INDICATOR NOTE: 

This Industrial Heater contains no user serviceable parts. In the unlikely event 

that your heater should need service, the digital display will indicate “E1",“E2” 

or “E3” please refer to the 

Error Code Troubleshooting Guide

 on the next 

page or contact:

World and Main (Cranbury), LLC 

 

324A Half Acre Rd, Cranbury, NJ 08512 USA 

 

tel. 800-221-6895, www.comfortzoneproducts.com

Because of its rugged design, 
superior engineering, and 
high quality craftsmanship, 
the heater requires little 
maintenance, With proper care, 
your electric heater should last 

a lifetime, but seasonal cleaning 

is recommended to maintain the 

efficiency of the heater. 

 WARNING: 

To prevent possible electric shock, all power must be shut off at the main service before inspecting or cleaning. 

Use care to prevent damage to internal heater wiring when cleaning element. Make sure all connections remain tight 

and all wiring is routed away from element fins when reassembling the unit. Allowing wiring to touch the element fins 

could result in a fire hazard.

HEATING
ELEMENT

Figure 8

FAN AND MOTOR

PROTECTIVE
GRILLE

Figure 9

ADJUSTING AIR FLOW DIRECTION: 

Turning the unit –

 If the unit has been installed with a single lag bolt, as shown in the 

Figure 3a

, simply turn the 

entire unit as needed to adjust air flow, as shown in 

Figure 7

.

Tilting the unit –

 Loosen the bracket screws 

(see Figure 4)

.

NOTE:

 To tilt the heater, it must be mounted in bottom keyhole 

slots of mounting brackets to maintain adequate clearance and 

prevent possible overheating.

CAUTION:

 This heater is hot when in use. To avoid burns, do not 

let  bare skin touch hot surfaces. If provided, use handles when 

moving this heater. 

ADJUSTING THE LOUVERS TO THE DESIRED POSITION:
NOTE:

 The louvers are designed the way so they can’t be 

completely closed. Do not attempt to defeat this feature, damage 
to the unit can result.

Figure 7

Rotate

OPERATING INSTRUCTIONS

Содержание CZ225ERLSCN

Страница 1: ...94 4148 8 a m 8 p m EST Monday Sunday You could also contact us at partsplus lowes com or visit www lowespartsplus com Heavy duty electric utility heaters are designed to meet a variety of heating requirements Heat output ranges from 10 239 BTUs per hour to 20 477 BTUs per hour Heaters feature horizontal and vertical flow built in thermostat and high limit thermal cutout UTILITECH and logo design ...

Страница 2: ... indoor locations Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended IMPORTANT SAFETY FEATURES POWER INDICATOR LIGHT The power indicator light located above ON OFF power switch on the control panel lights when the heater is turned on by pressing the power button AUTOMATIC OVERHEAT PROTECTION THERMAL CUTOUT T...

Страница 3: ...240 volt electric power Never use with an extension cord or relocatable power tap outlet power strip WARNING This heater is not suitable for use in hazardous locations as defined by the national fire protection association NFPA in the United States This heater has hot and arcing sparking parts inside Do not use in areas where gasoline paint or flammable liquids are used or stored This heater is no...

Страница 4: ...er Attach the cable connectors to the unit See Figure 5 and slide the 8 guage wire through the cable connector NOTE This appliance must be grounded NOTE Proper size fuses and circuit breakers in accordance with the National Electric Code must be used NOTE The appliance must connect to a current protection circuit or device at 50A or more before connecting to power supply Higher protection limits m...

Страница 5: ... on either the unit or the remote The temperature display will blink while it is being adjusted When the desired temperature is reached it will take about 5 seconds to accept the setting Once the display stops flashing the room temperature will reappears on the LED screen to indicate the desired temperature is set While the temperature setting is in either LOW or MEDIUM or HIGH mode the unit will ...

Страница 6: ...gh quality craftsmanship the heater requires little maintenance With proper care your electric heater should last a lifetime but seasonal cleaning is recommended to maintain the efficiency of the heater WARNING To prevent possible electric shock all power must be shut off at the main service before inspecting or cleaning Use care to prevent damage to internal heater wiring when cleaning element Ma...

Страница 7: ...ire Guage for Supply Connections Inadequate Current Amp Rating on Breaker Improper Heater Shut Down Detached or Loose Connection at Room Temperature Sensor Moisture Entrapment in Heater Electrical Short to Ground at Room Temperature Sensor Supply Connections Improperly Wired Insufficient Service Loop on Supply Connections Electrical Short to Ground Fan Blade Not Spinning Fan Operates at Reduced Sp...

Страница 8: ...ses due to neglectful operation All implied warranties including the warranties of merchantability and of fitness of purpose if applicable are hereby limited in duration to the period of one year from the date of original retail purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you Incidental or consequential damages arisi...

Отзывы: