Utilitech Pro 119032 Скачать руководство пользователя страница 4

4

This pump tank is designed and intended for cold (ambient temperature) water storage at a maximum 

pressure of 100 PSIG, any use other than with cold water, or at a sustained or instantaneous pressure 

in excess of 100 PSIG is UNSAFE. A pressure relief valve of adequate size must be incorporated in 

the system. The relief valve must be selected to pass the full capacity of the pump when the pressure 

in this tank is 100 PSIG or more. Consult pump manufacturer for pump capacity at relief pressure. 

The manufacturer of this tank does not accept any liability or other responsibility for personal injury or 

property damage resulting from improper use, installation or operation of this tank, or of the system of 

which it is a part.
Failure to follow these instructions can cause tank to explode and result in DEATH, SERIOUS BODILY 

INJURY OR PROPERTY DAMAGE.

Install a 100 P.S.I. or less pressure relief valve directly into a fitting of the plumbing. Position the valve 

downward and provide tubing so that any discharge will exit only within 6 inches above, or at any 

distance below the structural floor. Be certain that no contact is made with any live electrical part. The 

discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, 

over 15 feet, or in use of more than two elbows can cause restriction and reduce the discharge capacity 

of the valve.
No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing 

directly to discharge drain unless a 6 in. air gap is provided. To prevent bodily injury or hazard to life, the 

valve must be able to discharge large quantities of water  should circumstances demand. If the discharge 

pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

  • Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or

 

  other restrictions. 

  • Must not be plugged or blocked. 
  • Must  be  installed  so  as  to  allow  complete  drainage  of  both  the  pressure  relief  valve  and  the 

 

  discharge pipe. 

  • Must not have any valve between the relief valve and tank.

The complete pump, tank pressure relief valve, pressure switch and piping system MUST be protected 

against below freezing temperature. Failure to do so could cause tank to explode and result in DEATH, 

SERIOUS BODILY INJURY OR PROPERTY DAMAGE.
The pump tanks are designed for operation on water systems with working pressure not to exceed 

100 PSI. Pressure exceeding this could become hazardous, and will void any and all warranties, either 

written or implied.

IMPORTANT

It will be necessary to expel all air from piping after new installations, repriming and after pumps have 

been disassembled for repair. To purge the air, first open a faucet the greatest distance from the pump. 

With the pump being allowed to run, wait until a steady stream of water is coming from the faucet. At 

this time, close the faucet for several short intervals.
If, after this, air is still in the lines, check on the suction side of the pump for piping leaks.

When standard type tanks are replaced with this tank, all air charging devices, bleeder orifices and air 

volume controls must be removed.
The pump tank has been shipped with a factory precharge as indicated on the tank label. If your pump 

start-up pressure is different from the factory precharge, adjust the tank pressure with the empty tank to 

your pump start-up pressure. This can be accomplished by simply bleeding air from valve in the top of 

the tank with an accurate pressure gauge. Using the same standard air charging valve in the top tank, 

a tire pump  can be used to raise the tank pressure. Raise the pressure slowly, checking it periodically 

with an accurate tire pressure gauge, until the desired pressure is reached.

Содержание 119032

Страница 1: ...ing parts Before returning to your retailer call our Technical Assistance Team at 1 800 549 6233 7 00 a m 7 00 p m CST Monday Friday ITEM 119032 PUMP TANK MODEL LLT25 Fran ais p 13 Espa ol p 25 PRINTE...

Страница 2: ...dous situation which if not avoided could result in death or injury CAUTION indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury All safety message...

Страница 3: ...er installation be sure the pressure switch is set low enough to shut the pump off If all valves are closed and the pressure switch setting is too high the pump will run continuously without water flo...

Страница 4: ...damage The Discharge Pipe Must not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restrictions Must not be plugged or blocked Must be installed so as...

Страница 5: ...1 in NPTF Weight in Pounds 39 5 PIPING PVC pipe is shown in the illustrations but copper or galvanized steel pipe may be used if desired All piping must be clean and free of all foreign matter ALL JOI...

Страница 6: ...e tank to service line One male 1 in PVC adapter One 1 in X 11 in tank cross Two 3 8 in plugs One 1 2 in boiler drain One 1 2 in street tee REMINDER All joints and connections must be airtight A singl...

Страница 7: ...of street tee TANK CROSS 3 4 in PRESSURE RELIEF VALVE 3 4 in BOILER DRAIN Figure 1 Step 1 STEP 2 Thread 1 in male PVC adapter into the inlet side of tank cross 1 in MALE PVC ADAPTER Figure 2 Step 2 S...

Страница 8: ...ing the Tank Pressure The tank pressure must be set 2 PSI lower than the pump cut on pressure Check tank pressure with a standard air gauge valve at the top of the tank as needed Other Tank Installati...

Страница 9: ...9 NOTES...

Страница 10: ...10 NOTES...

Страница 11: ...11 NOTES...

Страница 12: ...tore serving your area The store representative will verify warranty registration with the manufacturer D WHAT THIS WARRANTY DOES NOT COVER 1 THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE...

Страница 13: ...pporter le produit votre d taillant appelez notre quipe d assistance technique au 1 800 549 6233 entre 7 h et 19 h HNC du lundi au vendredi ARTICLE No 119032 R SERVOIR POUR POMPE MOD LE No LLT25 Engli...

Страница 14: ...me pour viter les risques de blessures ou de mort DANGER indique un risque imminent qui entra nera la mort ou des blessures s il n est pas vit AVERTISSEMENT indique un risque potentiel pouvant entra n...

Страница 15: ...surez vous que le pressostat est r gl un niveau suffisamment bas pour arr ter la pompe Si toutes les valves sont ferm es et que le pressostat est r gl un niveau trop lev la pompe fonctionnera continue...

Страница 16: ...e le tuyau de sortie de la soupape ni tre muni de raccords de r duction ou de toute autre restriction Ne doit pas tre bouch ni bloqu Doit tre install de fa on que l on puisse effectuer le drainage com...

Страница 17: ...7 92 TUYAUX Les illustrations montrent des tuyaux en PVC mais des tuyaux en cuivre ou en acier galvanis peuvent galement tre utilis s Toute la tuyauterie doit tre propre et exempte de toute substance...

Страница 18: ...adaptateur m le en PVC de 2 54 cm Un croisillon de r servoir de 2 54 cm x 27 94 cm Deux bouchons de 0 95 cm Un drain de chaudi re de 1 27 cm Un t m le femelle de 1 27 cm RAPPEL Tous les joints et rac...

Страница 19: ...OIR SOUPAPE DE D CHARGE DE 1 9 mm DRAIN DE CHAUDI RE de 1 9 mm Figure 1 tape 1 TAPE 2 Ins rez l adaptateur m le en PVC de 2 54 cm dans le c t du croisillon du r servoir servant l entr e d eau ADAPTATE...

Страница 20: ...it tre r gl e 2 lb po2 plus bas que la pression de point de coupure de la pompe V rifiez la pression du r servoir au besoin l aide d un manom tre standard plac sur le dessus du r servoir Autres instal...

Страница 21: ...21 NOTES...

Страница 22: ...22 NOTES...

Страница 23: ...23 NOTES...

Страница 24: ...egistrement de la garantie aupr s du fabricant D CE QUI N EST PAS COUVERT PAR CETTE GARANTIE 1 CETTE GARANTIE LIMIT E CONSTITUE LA SEULE GARANTIE OFFERTE PAR LE FABRICANT ET PR VAUT SUR TOUTE AUTRE GA...

Страница 25: ...ame a nuestro equipo de asistencia t cnica al 1 800 549 6233 de lunes a viernes de 7 a m a 7 p m hora central est ndar ART CULO 119032 TANQUE DE BOMBA MODELO LLT25 English p 1 Fran ais p 13 IMPRESO EN...

Страница 26: ...onar la muerte o lesiones PRECAUCI N indica una situaci n de posible peligro que de no evitarse puede ocasionar lesiones menores o moderadas Todos los mensajes de seguridad generalmente indican el tip...

Страница 27: ...le en un lugar lo suficientemente bajo para apagar la bomba Si todas las v lvulas est n cerradas y el ajuste del interruptor de presi n tiene un valor muy alto la bomba funcionar continuamente sin flu...

Страница 28: ...ubo de salida o tener acopladores reductores u otras restricciones No debe estar atascado o bloqueado Debe estar instalado de manera que permita el desag e completo de la v lvula de descarga de presi...

Страница 29: ...A En las ilustraciones se muestran tubos de PVC pero pueden usarse tubos de cobre o de acero galvanizado si se desea Todas las tuber as deben estar limpias y libres de sustancias extra as TODAS LAS U...

Страница 30: ...nes de 3 8 pulgada Un desag e de caldera de 1 2 pulgada Un conector en T de 1 2 pulgada RECORDATORIO todas las uniones y conexiones deben ser herm ticas Las filtraciones de un solo orificio peque o im...

Страница 31: ...VULA DE DESCARGA DE PRESI N DE 3 4 DE PULGADA DESAG E DE CALDERA DE 3 4 DE PULGADA Figura 1 Paso 1 PASO 2 EnrosqueeladaptadormachodePVCde1pulgada en el lado de entrada del cruce del tanque ADAPTADOR M...

Страница 32: ...UE VERTICAL Ajuste de la presi n del tanque La presi n del tanque debe ajustarse a 2 PSI menos que la presi n reducida Revise la presi n del tanque con una v lvula de calibre de aire en la parte super...

Страница 33: ...33 NOTAS...

Страница 34: ...34 NOTAS...

Страница 35: ...35 NOTAS...

Страница 36: ...ienda Lowes que opere en su rea El representante de la tienda verificar el registro de la garant a con el fabricante D LO QUE ESTA GARANT A NO CUBRE 1 ESTA GARANT A LIMITADA SER LA GARANT A EXCLUSIVA...

Отзывы: