General
The normal routine of running the machine is very simple. If it is carried out strictly at all times, many years of
trouble free service can be expected.
We emphasise two points of paramount importance-
1. Filtration of incoming air of gas
2. Lubrication
If possible provide a logbook so that the operator can enter daily readings. After several months a record will show
whether the machine is performing as it did originally. If readings are to be taken the following are all that is
required. Inlet and outlet air temperatures, suction conditions and oil drip rate.
A typical layout for the log book is shown in the table below.
Machine Log Book
Date
Inlet Gas Temp.
Discharge Gas Temp.
Inlet Conditions
Oil Level
Technical Specification
The model, machine serial number, year of manufacture, temperature class and zone rating for the machine
appear on the machine data plate, other machine data can be found in the following table.
Units Model
700
Maximum Pressure (Air)
mbar
74
Speed – Maximum
R.P.M.
10000
Speed - Minimum
R.P.M.
4500
Max. Volume at Max. Speed (Air)
m
3
/hr 455
Max. Volume at Max. Speed (Bio Gas (SG=0.8))
m
3
/hr 455
Max. Absorbed Power at Max. Speed (Air)
kW
1.7
Max. Absorbed Power at Max. Speed (Bio Gas)
kW
1.5
Maximum Ambient Temperature
°
C
40
Surface Temperature at Max. Press. at Max. Speed (Air)
°
C
Moment of Inertia
kg m
2
0.004
Noise Level at 1 metre
db (A)
73 - 84
Weight kg
11
Note: Machine must not be used on any other gas than originally specified. Utile Engineering must be consulted if
traces of any other gas are introduced into the machine.
General
Operating Principle
General,
Technical Specification
Nameplate Data
Machine Model eg 700/90
Machine Serial Number
(Always quote this in
correspondence)
Logo
Temperature Classification
450
°
C – T1 300
°
C – T2
200
°
C – T3 135
°
C – T4
100
°
C – T5 85
°
C – T6
CE Marking
Contact address & numbers
Zone Rating
0 – Very High Protection - Gas Area
1 – High Protection - Gas Area
2 – Normal Protection - Gas Area
Year of
Manufacture
Ex
Mark
Equipment Group
I – Mines
II – Surface Indus
Gas/Dust
G – Gas
D - Dust
Protection Category
1–V.High Protection
2–High Protection
3–Normal Protection