background image

 

Multi-Purpose Housing Installation Instructions 

Product summary 

The Multi-Purpose Housing (60-928) is designed to hold 

several different circuit boards. It can be adapted for many 

different installation situations. The Multi-Purpose Housing has 

the following features: 

• 

Space for an optional backup battery. 

• 

Holes for an antenna  

• 

Temporary supports for pre-wiring of boards. 

• Wiring 

knockouts. 

• Combined 

wall/cover 

tamper 

protection. 

Figure 1: Multi-purpose housing features 

Optional 

Backup 

Battery

Optional 
Antenna 

Holes

Wall/Cover 

Tamper

Adjustable Board 

Supports

Temporary 

Supports (Pre-

Wiring)

Circuit Board 

Supports

Wiring 

Knockouts

Wiring 

Knockouts

 

Accessory kit 

The Multi-Purpose Housing comes with the following 

accessories: 

• 

Two screws for adjustable supports. 

• 

One Tinnerman nut for the cover locking mechanism. 

• 

Anchors and screws for mounting 

• 

One screw for the cover locking mechanism. 

• 

Two silicone caps for antenna holes and mounting of loop 

antenna. 

• 

Two rubber o-rings for plastic antenna housings. 

• 

One normally closed tamper switch with spring. 

Installing 6 in. (15.24 cm) circuit boards 

1.  Remove the adjustable board supports from the housing. 

2.  Remove the appropriate wiring knockout. 

3.  Attach housing to wall. 

Note

: Be sure adjustable board supports and knockouts are 

removed before mounting the housing. 

4.  Place board in temporary support. 

5.  Wire the board as needed. 

6.  Place the board on appropriate supports. 

7.  Position adjustable board supports as needed for board 

size (See the following figures). 

8.  Attach supports with screws. 

Figure 2: Installation of 2.3 x 6 in. (5.83 x 15.24 cm) circuit board 

2.30 in

(5.83 cm)

6.00 in

(15.24 cm)

 

Figure 3: Installation of 3.3 x 6 in. (8.56 x 15.24 cm) circuit board 

6.00 in

(15.24 cm)

3.37 in

(8.56 cm)

 

P/N 466-1959 • REV D • January 2011 