NX-7002N Installation Manual
Page 50
05/06/13
PSU
PSU Error
This LED indicates that there is a problem with the 3.8 V
Switched Mode Power Supply Unit (the modem power source is
too low).
REP
Reporting
This LED indicates that TCP/SMS reporting is taking place.
GPRS
GPRS Active
This LED indicates that the module is connected to the GPRS
network. This LED turns off when the module is no longer
connected to the GPRS network, for example, when it uses the
voice channel or CSD.
SIM
SIM Error
This LED indicates that the SIM card is blocked and a PUK code
is required to unblock it.
COM
GSM
Communication
This LED is for future use.
BUS
BUS
Communication
This LED indicates that the module is receiving messages over
the bus (from the control panel).
NET
Network OK
This LED indicates that the module is connected to the GSM
network (voice channel or CSD).
NetworX bus connector
Diagnostics
T
ECHNICAL SPECIFICATIONS
1.11 NX-7002N Technical specifications
Power supply voltage
9.0 - 14.5 Vdc
2%
Current consumption
- Nominal
30 mA at 13.8 Vdc
2%
- Maximum
up to 2 Amps peak
Battery
max. 12 V/7.2 Ah
Operating temperature
0 - 49° C
Humidity
Max 93% non condensating
Dimensions (PCB board only)
WxHxD
102 x 50 x 24 mm
Weight (PCB board only)
50 g
Environmental Class
Class II
This product was tested and certified to EN 50136-1-1:1998/A1:2001 and EN 50136-2-1:1998/A1:2001 for
Alarm transmission system performance ATS 5 (D3, M3, T4, S2, I3) for reporting over GPRS to the OH
Receiver.
Tested and certified by Telefication B.V.
According to EN 50131-1:2006 and A1:2009, this equipment can be applied in installed systems up to and
including Security Grade 2.