![Utax 5240L Скачать руководство пользователя страница 366](http://html.mh-extra.com/html/utax/5240l/5240l_user-manual_1064809366.webp)
10-10
Troubleshooting
Send error.
####
2101, 2102, 2103, 2201, 2202, 2203,
3101: The network cable is
disconnected or the hub that it is
connected to is not operating
properly. Check the cable and the
hub. Otherwise, the server name or
the host name of the SMTP server is
not set correctly. Use
Embedded Web
Server
and register the SMTP
server name and the host name
correctly.
2204: The E-mail size exceeds the
acceptable send data capacity.
Decrease the size or resolution of the
scanned data to be transmitted and
resend the E-mail.
5101, 5102, 5103, 5104, 7102, 720f:
Turn the main power switch off and
back on. If this error occurs several
times, make a note of the displayed
error code and contact your service
representative.(Refer to the
corrective action for the error
message “ An error has occurred.”)
9181: The scanned original exceeds
the acceptable number of pages of
999. Send the excess pages
separately.
—
Error occurred.
Turn the main power
switch off and on.
–
System error has occurred. Turn the
main power switch off and on.
—
Incorrect account ID.
–
The Account ID does not match.
Check the registered Account ID.
—
The phone receiver is
off the hook.
Hang Up.
–
Put down the receiver.
—
File is not found.
Job is canceled.
–
The specified file is not found. The
job is canceled. Press the
OK
key.
—
KPDL error. Job is
canceled.
–
The job is canceled. Press the
OK
key.
—
Print overrun. Job is
canceled.
–
The job is canceled. Press the
OK
key.
—
Inner Tray is full of
Paper.
Remove the paper.
–
Remove paper from the inner tray,
and press the
OK
key to resume the
job.
—
Unknown toner
Installed.
Is the installed toner
container our own brand?
We will not be liable for any damage
caused by the use of third party
supplies in this machine.
9-5
Error Message
Check points
Corrective Actions
Reference
Page
Содержание 5240L
Страница 1: ...CD 5140L 5240L user manual Digital Multifunktional systems ...
Страница 2: ......
Страница 61: ...2 Preparation before Use 2 27 5 Click Close The machine is registered to the PC ...
Страница 138: ...4 18 Copying Functions ...
Страница 144: ...5 6 Sending Functions NOTE Press the Reset key to reset the settings selected in Function Menu ...
Страница 164: ...5 26 Sending Functions ...
Страница 169: ...6 6 5 Document Box NOTE Press the Reset key to reset the settings selected in Function Menu ...
Страница 412: ...11 38 Management 5 After completing checking the count press the OK key The screen returns to the menu for the account ...
Страница 438: ...Appendix 26 ...
Страница 445: ......
Страница 446: ...TA Triumph Adler GmbH Ohechaussee 235 22848 Norderstedt Germany ...