Low power WIFI module user manual
Jinan USR IOT Technology Limited
Page 56/72
+ok=<log> <CR>< LF ><CR>< LF >
Parameters:
log: feedback the status of remote upgrade;
Note:
After execute this command, the USR-WIFI232-T will automatic start upgrade base on
the
setting of UPURL, UPFILE command contents;
4.2.2.58. AT+WEBU
Function: Set/ Query webpage user name and password;
Format:
Query Operation
AT+ WEBU<CR>
+ok=<username,password> <CR>< LF ><CR>< LF >
Set Operation
AT+ WEBU=<username,password><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
username: User Name, within 15 characters, not support empty.
password: password, within 15 characters, support empty.
4.2.2.59. AT+MSLP
Function: Set/Query deep sleep/standby mode parameters;
Format:
Query Operation
AT+ MSLP<CR>
+ok=<ret><CR>< LF ><CR>< LF >
Set Operation
AT+ MSLP=<mode><CR>< LF ><CR>< LF >
Parameters:
ret:
normal: normal mode (100ms interval)
mode:
normal: normal mode (100ms interval)
standby: WiFi shut down mode
4.2.2.60. AT+NTPRF
Function: Set /Query time calibration interval
Format:
Query Operation
AT+ NTPRF<CR>
+ok=<num><CR>< LF ><CR>< LF >
Set Operation
AT+ NTPRF=<num><CR>
+ok<CR>< LF ><CR>< LF >
Parameters: