Low power WIFI module user manual
Jinan USR IOT Technology Limited
Page 57/72
num
:
time calibration inverval
,
range:0~720, default:30 minutes, 10 minutes for
each step, set 0 means no time calibration automatically.
4.2.2.61. AT+NTPEN
Function: Enable/Disable time calibration function.
Format:
Query Operation
AT+ NTPEN<CR>
+ok=<status><CR>< LF ><CR>< LF >
Set Operation
AT+ NTPEN=<status><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
status
:
status of time calibration
on
:
Enable time calibration
off
:
Disable time calibration
4.2.2.62. AT+NTPTM
Function: Query network time
Format:
Query Operation
AT+ NTPTM<CR>
+ok=<time><CR>< LF ><CR>< LF >
Parameters:
time
:
networ time, for example: 2013-10-9 16:10:42 Wed
,
if it shows Not
Available means that the time calibration function is not enabled or the module
doesn’t connect to the internet.
4.2.2.63. AT+WRMID
Function: Set module ID;
Format:
Set Operation
AT+ WRMID=<wrmid> <CR>< LF ><CR>< LF >
Parameters:
wrmid:
set module’s ID (within 20 characters).
4.2.2.64. AT+RLDEN
Function: Set/Query GPIO45 function status
Format:
Query Operation
AT+RLDEN<CR>
+ok=<status><CR>< LF ><CR>< LF >
Set Operation
AT+RLDEN=<status><CR>