User Manual
Your TrustWorthy Industrial IoT Partner
www.pusr.com
66
Fig. 80
Synchronizing serial port parameters
5.3.1. PUSR customized RFC2217 protocol
Table 22 Com Port Control commands
Name
Header
Baud rate
Serial parameter definition
Sum check
Length(bytes)
3
3
1
1
Description
Fixed
Big endian,
e.g.
600(00 02
58)
Data bits/stop bits/parity
bits setting.
AS shown in the table 23
below
Check sum of 4 bytes of
baud rate and serial
parameter definition, retain
115200,N,8,1
55 AA 55
01 C2 00
03
C6
9600, N,8,1
55 AA 55
00 25 80
03
A8
Table 23 Serial parameter definition
Bit Position
Function
Value
Description
1:0
Data bits
10
7 Data bits
11
8 Data bits
2
Stop bits
0
1 Stop bits
1
2 Stop bits
3
Parity bit enable
0
disable the parity bit
1
Enable the parity bit
5:4
Parity bit type
00
ODD
01
EVEN
10
Mark
11
Space
7:6
undefinition
00
Please write 0