background image

MODEL MDSCN103CN,
MODEL MDSCN103LCN
IoPHIC

®

  SMOKE & FIRE ALARM,

CARBON MONOXIDE ALARM &
NATURAL GAS ALARM

120VAC 60 Hz 100 mA Max.

MODEL MDSCN111CN,
MODEL MDSCN111LCN
IoPHIC

®

  SMOKE & FIRE ALARM,

CARBON MONOXIDE ALARM &
NATURAL GAS ALARM

120VAC 60 Hz 100 mA Max.

THANK YOU for purchasing this combination alarm. This manual includes important information
regarding where to install the alarm, how to operate, maintenance, testing and product features. It
also includes tips and information which could help protect you and your family.

PLEASE READ AND SAVE!

Table of Contents:

Page #

Alarm Limitations and Functions ......................................................... 2

What You Should Know About CO ........................................................ 3

What You Should Know About Natural Gas ......................................... 3

Basic Safety Information ...................................................................... 5

Recommended Location of Alarms ..................................................... 6

Where Alarm Should Not Be Installed ............................................. 6, 7

Installation Instructions ........................................................................ 7

Electrical Shock Hazard ....................................................................... 7

Locking / Tamper Feature ................................................................ 7, 8

Wiring Instructions ............................................................................... 8

Operation, Testing & Maintenance ..................................................... 10

QUICK FIND

®

 

Alarm Originating Feature & Reset ............................. 10

What To Do If The Alarm Sounds ....................................................... 10

CO & Smoke Alarm Silence Feature ................................................... 11

Testing & Maintenance ....................................................................... 12

Battery Backup Replacement ............................................................. 13

CO & Natural Gas Alarm Limitations ................................................. 13

Operational Summary .................................................................. 16, 17

Warranty ................................................................................ Back Cover

Содержание UNIVERSAL MDSCN103CN

Страница 1: ...ld help protect you and your family PLEASE READ AND SAVE Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety...

Страница 2: ...ETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR...

Страница 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Страница 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Страница 5: ...e presence of CO or natural gas which reaches the sensor NOTE For your convenience we provide separate labels for the French language product markings If you choose to utilize those markings remove th...

Страница 6: ...et 6m from the sources or combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6m distance is not possible in modular mobile or smaller homes for example i...

Страница 7: ...is alarm to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting test...

Страница 8: ...only present in models MDSCN111CN MSDCN103CN MICN109CN MICN102CN MCN108CN and MCN105CN therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnec...

Страница 9: ...40 seconds to indicate proper operation IMPORTANT The battery backup is designed to provide short term emergency power to the Smoke CO and Gas Alarm Actual backup time depends on the strength freshnes...

Страница 10: ...ted the alarm will sound 3 chirps approx every 20 seconds Reset the alarm If the unit does not reset replace the alarm END OF SERVICE LIFE ALARM When it is time to replace your alarm which is approxim...

Страница 11: ...on the level of CO detected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dange...

Страница 12: ...t to natural gas outside of a controlled labatory environment can produce an explosion and death NEVER use a gas range or an open flame of any kind to test this alarm You might accidentally damage or...

Страница 13: ...of the home and not reach the alarm installed on a different level For example CO or gas in the basement may not reach an alarm on the second level near the bedrooms For this reason we recommend you...

Страница 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Страница 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Страница 16: ...ectedGASalarmhassensed GAS causing all interconnected units to sound If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps...

Страница 17: ...approx every 20 seconds Off Off Condition Product End of Service Life Notification Recommendation Replacethealarmimmediately Theproduct end of service life notification can be temporarily silenced fo...

Страница 18: ...ES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREAT...

Отзывы: