Good ventilation is recommended when household cleaning supplies or similar contaminants
are used.

Excessive spillage or reverse venting of fuel-burning appliances caused by outdoor ambient
conditions, such as:

Wind direction and/or velocity, including high gusts of wind. Heavy air in the vent pipes (cold/
humid air with extended periods between cycles).

Negative pressure differential resulting from the use of exhaust fans.

Simultaneous operation of several fuel-burning appliances competing for limited internal air.

Vent pipe connections vibrating loose from clothes dryers, furnaces or water heaters.

Obstructions in or unconventional vent pipe designs which can amplify the above situations.

Page 7

THIS ALARM WILL NOT WORK WITHOUT 120 VAC POWER AND A GOOD
BATTERY PROPERLY INSTALLED. THE ALARM SHOULD BE TESTED WHEN
INSTALLED AND THEN TESTED WEEKLY AFTER THAT.

INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY.

Installation of this alarm must conform to the electrical codes in your area and any other
local or building codes that may apply. Wiring and installation must be performed by a licensed
electrician. Failure to follow these guidelines may result in injury or property damage.

This alarm must be powered by a 24-hour, 120V AC 60Hz circuit. Be sure the circuit cannot be
turned off by a switch, dimmer or ground fault circuit interrupter. Failure to connect this
alarm to a 24-hour circuit may prevent it from providing constant protection.

IMPORTANT: Do not subject this alarm to megger, high voltage or high-pot tests. Remove the
alarm(s) before high-potting tests occur on the circuit or system.

ELECTRICAL SHOCK HAZARD

Turn off power to the area where you will install this alarm at the circuit breaker or fuse box
before beginning installation. Failure to turn off the power before installation may result in
serious electrical shock, injury or death.

CAUTION: THIS SMOKE, CO AND NATURAL GAS ALARM IS SEALED. THE COVER
IS NOT REMOVABLE

!

• A mounting bracket is provided on the back of the alarm.

• Remove the mounting bracket from the back of the alarm by holding the mounting bracket and

twisting the alarm in the direction indicated by the "TWIST TO REMOVE" arrow on the side of the
alarm base.

OPTIONAL TAMPER RESISTANT FEATURES:

 There are two separate tamper resistant locking

features provided for this model. Activating one or both of these features deters someone from
removing the smoke alarm from the mounting bracket or removing the battery from the alarm. The
breakaway locking pins are clearly marked and molded into the mounting bracket. Refer to the
diagram on the next page.

TO ACTIVATE THE LOCKING FEATURES:

 Do not activate the locking features until you have

activated the battery, mounted the smoke alarm to the bracket and tested the smoke alarm. Refer to
OPERATION, TESTING & MAINTENANCE instructions on Page 10.

1.

Detach the breakaway alarm locking pin from the mounting bracket.

ALARM/BRACKET

LOCKING PIN

BATTERY LOCKING PIN

Содержание UNIVERSAL MDSCN103CN

Страница 1: ...ld help protect you and your family PLEASE READ AND SAVE Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety...

Страница 2: ...ETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR...

Страница 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Страница 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Страница 5: ...e presence of CO or natural gas which reaches the sensor NOTE For your convenience we provide separate labels for the French language product markings If you choose to utilize those markings remove th...

Страница 6: ...et 6m from the sources or combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6m distance is not possible in modular mobile or smaller homes for example i...

Страница 7: ...is alarm to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting test...

Страница 8: ...only present in models MDSCN111CN MSDCN103CN MICN109CN MICN102CN MCN108CN and MCN105CN therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnec...

Страница 9: ...40 seconds to indicate proper operation IMPORTANT The battery backup is designed to provide short term emergency power to the Smoke CO and Gas Alarm Actual backup time depends on the strength freshnes...

Страница 10: ...ted the alarm will sound 3 chirps approx every 20 seconds Reset the alarm If the unit does not reset replace the alarm END OF SERVICE LIFE ALARM When it is time to replace your alarm which is approxim...

Страница 11: ...on the level of CO detected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dange...

Страница 12: ...t to natural gas outside of a controlled labatory environment can produce an explosion and death NEVER use a gas range or an open flame of any kind to test this alarm You might accidentally damage or...

Страница 13: ...of the home and not reach the alarm installed on a different level For example CO or gas in the basement may not reach an alarm on the second level near the bedrooms For this reason we recommend you...

Страница 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Страница 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Страница 16: ...ectedGASalarmhassensed GAS causing all interconnected units to sound If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps...

Страница 17: ...approx every 20 seconds Off Off Condition Product End of Service Life Notification Recommendation Replacethealarmimmediately Theproduct end of service life notification can be temporarily silenced fo...

Страница 18: ...ES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREAT...

Отзывы: