WHAT TO DO IF CARBON MONOXIDE IS DETECTED:

If you hear the alarm horn sound 4 beeps, a 2 second pause (and then repeat),

carbon monoxide has been detected. Evacuate everyone from the building.

OPERATION, TESTING & MAINTENANCE

OPERATION:

 The alarm is operating once the AC power is connected and turned on.  When products of

combustion are sensed, the alarm sounds a loud alarm which continues until the air is cleared.
This alarm incorporates the NFPA recognized horn signal for evacuation. During alarm mode, the
horn produces three beeps followed by a two second pause and then continually repeats.

READY/ACTIVE CONDITION:

 The green LED is on and blinks off once approx. every 20 seconds

to indicate the alarm is properly functioning.

LOCAL ORIGINATING SMOKE ALARM CONDITION:

 The green LED turns off and the red LED

blinks on approx. every second while the alarm emits a loud, pulsating alarm sound.

NON-ORIGINATING SMOKE ALARM CONDITION:

 The red LED is off and the alarm emits a loud,

pulsating alarm.

GREEN LED:

 The green LED is off and blinks on approx. every 40 seconds whenever AC power is

turned off.

CO ALARM:

 The alarm signal is 4 beeps, 2 second pause, repeat. The red LED blinks on in sync

with the cycle of 4 beeps.

GAS ALARM:

 The alarm signal is 1 beep, 1 second pause, repeat. The blue LED blinks on in sync

with the horn beep every second.

NUISANCE ALARM:

 If the horn signals and the red or blue LED’s blink on for no apparent reason

and no obvious hazard is present, please verify that the alarm is mounted in the correct location.
Reset the alarm as instructed in the Operational Summary.

SMOKE  ALARM LATCHING LED INDICATOR:

 The alarm had previously detected smoke and had

alarmed. The red LED is off and blinks on approx. every 5 seconds until reset. Follow the reset
instructions to remove the latching LED.

CO ALARM LATCHING LED INDICATOR:

 The alarm had previously detected CO and had

alarmed. The red LED is off and blinks on approx. every 5 seconds until reset. Follow the reset
instructions to remove the latching LED.

GAS ALARM LATCHING LED INDICATOR:

 The alarm had previously detected GAS and had

alarmed. The blue LED is off and blinks on approx. every 5 seconds until reset. Follow the reset
instructions to remove the latching LED.

TROUBLE / SERVICE ALARM:

 Periodically, the alarm measurement circuit is tested. If an error

is detected, the alarm will sound 3 chirps approx. every 20 seconds. Reset the alarm. If the unit
does not reset, replace the alarm.

END-OF-SERVICE LIFE ALARM:

 When it is time to replace your alarm, which is approximately

7 years of operation from initial power up, the alarm will sound 2 chirps approx. every 20 seconds.
Replace alarm immediately. The product end-of-service life notification can be temporarily silenced
for a 10 hour period for up to 20 days. After 20 days, the warning cannot be silenced. The alarm
should be replaced immediately.

RESET THE ALARM:

 Press the TEST/SILENCE button for 10 seconds, or until the blue LED turns

on, and then release. This will clear the alarm latching LED's and clear the alarm origination. Reset
after each alarm event.

TESTING:

 Test by pushing the Test button on the alarm cover until the alarm sounds, then release.

The alarm will sound 3 beeps, approx. 2 second pause, 3 beeps, approx. 6 second pause, 4 beeps,
approx. 5 second pause, 1 beep. The test sequence lasts approx. 20 seconds. The alarm sounds
if all electronic circuitry and horn are working. If no alarm sounds, the alarm may have a power
supply failure. 

Test the alarm weekly to assure proper operation.

ALARM ORIGINATION:

 QUICK FIND

®

 Alarm Origination - In an interconnected system consisting

of any of these models: 5304, MI106, MDS107, MCN108, MICN109, MDSCN111, MP117, it may
be difficult to determine which alarm initiated the alarms to sound during an alarm event. This
QUICK FIND

®

 feature will immediately allow you to locate the originating alarm once the alarms

have stopped sounding. To initiate QUICK FIND

®

, press the Test/Silence button on any alarm.

After releasing the button, the test sequence on this alarm will begin and last 5-20 seconds, and
then stop. The specific test sequence horn pattern is designated by the alarm type. Once this test
sequence ends, the originating alarm continues to sound for approx. 50 seconds, which provides
ample time to locate the originating alarm. Remember to reset tthe originating alarm in order to
clear the QUICK FIND

®

 alarm origination and to return your system to normal operation. Refer to

the wiring instructions model interconnect compatibility section of this manual for additional
information. In a non-interconnected installation, it is necessary to test each alarm by pressing
and releasing the Test/Silence button to determine the originating alarm.

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO), which can kill you.
In other words, when your CO Alarm sounds, you must not ignore it!

Содержание UNIVERSAL MDSCN103CN

Страница 1: ...ld help protect you and your family PLEASE READ AND SAVE Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety...

Страница 2: ...ETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR...

Страница 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Страница 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Страница 5: ...e presence of CO or natural gas which reaches the sensor NOTE For your convenience we provide separate labels for the French language product markings If you choose to utilize those markings remove th...

Страница 6: ...et 6m from the sources or combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6m distance is not possible in modular mobile or smaller homes for example i...

Страница 7: ...is alarm to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting test...

Страница 8: ...only present in models MDSCN111CN MSDCN103CN MICN109CN MICN102CN MCN108CN and MCN105CN therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnec...

Страница 9: ...40 seconds to indicate proper operation IMPORTANT The battery backup is designed to provide short term emergency power to the Smoke CO and Gas Alarm Actual backup time depends on the strength freshnes...

Страница 10: ...ted the alarm will sound 3 chirps approx every 20 seconds Reset the alarm If the unit does not reset replace the alarm END OF SERVICE LIFE ALARM When it is time to replace your alarm which is approxim...

Страница 11: ...on the level of CO detected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dange...

Страница 12: ...t to natural gas outside of a controlled labatory environment can produce an explosion and death NEVER use a gas range or an open flame of any kind to test this alarm You might accidentally damage or...

Страница 13: ...of the home and not reach the alarm installed on a different level For example CO or gas in the basement may not reach an alarm on the second level near the bedrooms For this reason we recommend you...

Страница 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Страница 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Страница 16: ...ectedGASalarmhassensed GAS causing all interconnected units to sound If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps...

Страница 17: ...approx every 20 seconds Off Off Condition Product End of Service Life Notification Recommendation Replacethealarmimmediately Theproduct end of service life notification can be temporarily silenced fo...

Страница 18: ...ES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREAT...

Отзывы: