PORTABLE LPV TREATER
Electrical Operation
Section
D
This section provides a general overview and description of the operator controls for
the Portable LPV Treater.
USC recommends the use of a surge protection device with a
minimum rating of 400 Joules for all automated main control
panels.
General Panel Descriptions:
All three panels are located side by side on the right side of the trailer at the center.
The U-Connect-Pro Control Panel is an enclosure that contains the HP T620 Thin
Client. This device converts the user supplied internet signal and sends it to the
main control panel. Power to this panel is supplied from a power cable to a
standard 115V outlet.
The LPV Treater Control Panel is an enclosure that contains the electrical
components required to actuate the seed treater. This includes the VFDs
for the seed wheel and atomizer. Power for the treater is supplied here.
Power to this panel is hard wired.
The Automated Main Control Panel is a plug connected enclosure. It contains
the PLC (Programmable Logic Controller) as well as the HMI (Human Machine
Interface) touch screen. The operator is able to control the entire system through
the HMI. Power to this panel is supplied from a power cable to a standard 115V
outlet.
HIGH VOLTAGE ~
Always disconnect the power source
before working on or near the control panel or lead wires.
HIGH VOLTAGE
~
Use insulated tools when making
adjustments while the controls are under power.
AUTHORIZED PERSONNEL only shall work on the control
panel. Never allow anyone who has not read and familiarized
themselves with the owner’s manual to open or work on the
control panel.
NOTICE