background image

The Trim Pieces

 

 
Trim pieces

 come in two types and sizes. One type is 

Non-Powered Trim

 pieces and the other is 

Powered Trim

 pieces. 

POWERED TRIM PIECES 

Powered trim pieces are the wired trim. These are used to finish one of the two open edges of the floor 
while hiding the wires that supply power. The floor panels are plugged into the sockets of the powered 
trim and then the pieces are secured to the floors by way of stainless steel screws. 

Po ered e te sio s are used  et ee  the  ai  po er  a le’s  or er tri  a d a other po ered 

extension or powered end piece.  
Powered end pieces are always used at the end of a length. (See Figure 1-5)  

Figure 1-3:

 

 
 

 

 

 

 

 

 

 

8 foot powered extension 

                  

   

                                       

 

 

                 (95 

13/16

 

 

. )

 

 
 

 

 

 

 

 

 

 

8 foot powered end piece 

 

 

 

 

 

 

 

                 

 

     (89 

7/8

 

 

. )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 foot powered end piece 

 

 

 

 

 

 

 

 

 

 

     (41 

7/8

 

 

. )

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

NON-POWERED TRIM PIECES 

Non-powered trim pieces have no wiring. These are used to finish the second open floor edge. Trim 
extensions are used for extending to a jointing four or eight foot length. End pieces are used to finish the 
end of a length. These trim pieces do not connect to each other. Rather they connect directly to the 
floor sections by way of stainless steel screws. 

Figure 1-4:

 

 

8 foot trim extension    

 

 

        (95 

13/16

 

 

. )

 

 

 
8 foot trim end piece 

 

 

 

          (89 

7/8

 

 

. ) 

 

 
4 foot trim end piece 

 

 

 

 

 

 

 

 

          (41 

7/8

 x 

. ) 

 

 
 
NOTE:

 

The optional slopped edging is secured to the trim pieces with special screws-in holes.  

 
 

The ARCH Portable Lighted Dance Floor System 

Copyright USA Dance Floor, LLC 

  

 

Содержание ARCH-RGB

Страница 1: ...The ARCH RGB Portable Lighted Dance Floor System SETUP and OPERATION INSTRUCTIONS A product of USA Dance Floor LLC Made in the U S A...

Страница 2: ...t are open or have no trim These open edges are completed when connected to a jointing panel However these open edges will need trim pieces attached all along two edges of the finished setup See the s...

Страница 3: ...ransported or stored up right on its edge Figure 1 2 shows the proper orientation Figure 1 2 Only rest the floor on this side when loading or storing upright on its edge Note Always tuck the short ext...

Страница 4: ...t the end of a length See Figure 1 5 Figure 1 3 8 foot powered extension 95 13 16 8 foot powered end piece 89 7 8 4 foot powered end piece 41 7 8 NON POWERED TRIM PIECES Non powered trim pieces have n...

Страница 5: ...pieces are used last or at the ends End trim pieces are 8 feet or 4 feet in length Figure 1 5 Powered End Trim Piece This is the shorter 8 foot Powered Extension Trim Piece Powered Extension Trim Piec...

Страница 6: ...ill may be used to secure screws only if it has a ratchet drive set at low torque Securing a screw does not mean to tighten it Securing a screw means that the top of the s re s head is le el ith or el...

Страница 7: ...ing as shown in figure 1 11 Figure 1 10 Dance Floor Surface Outside Edge inch Figure 1 11 Optional Aluminum Beveled Edging NOTE All new floors come with brand new never been used plugs and sockets Thi...

Страница 8: ...idea to power up and test the floors after assembling a row to confirm all connections tri end 8 e te sio tri 3 2 1 Third Floor Second Floor First Floor Panel Panel Panel 8 Tri end 6 5 4 Sixth Floor F...

Страница 9: ...this plug in The other is an L shaped corner floor trim piece that connects in the corner of the floor where the Powered and Non Powered trim pieces come together The plugs coming from this piece con...

Страница 10: ...e down as shown in Figure 1 16 Figure 1 16 Remove the four screws holding the cover to the Powered Extension Trim Piece This will expose the plug and socket for connecting to the main power connector...

Страница 11: ...Figure 1 17 There should never be any binding or cross threading Use a screwdriver to pry the holes inline and start screwing the bolt in See Fig 1 17 Only start it and leave it loose until all bolts...

Страница 12: ...ld look like Figure 1 21 Figure 1 21 NOTE If the bolt binds cross threads or won t start skip it It is ok to have a missing bolt here and there then to cross thread or bind it If a screw gets cross th...

Страница 13: ...Anyone handling the panels at anytime should always be wearing gloves To help prevent a static charge it is recommended that the gloves are made of cotton It is also recommended that anyone handling t...

Страница 14: ...will be flashing This means the floor will be black or off NOTE It is normal to see the floor flash white when first powered on To operate i sou d a ti atio ode press the t o Sou d A ti e utto s This...

Страница 15: ...Load regulation 0 5 RGB FLOOR PANEL LOAD at full on One panel draws 14 4 Watts 12VDC Maximum load 54 floor panels Sq footage 864 An optional DMX power supply is also available The DMX power supply tur...

Страница 16: ...rim Simply wet a clean rag with Goof Off and wipe WARNING There are sharp edges always wear gloves There are sharp edges Anyone handling the panels at anytime should always be wearing gloves To help p...

Отзывы: