3
Proper Installation
This water softening system must be properly installed and located in accordance with the
Installation Instructions before it is used or the warranty will be void.
Do not
install or store where it will be
exposed to temperatures below freezing or
exposed to any type of weather. Water
freezing in the system will break it. Do not
attempt to treat water over 100°F.
Do not
install in direct sunlight. Exces-
sive sun or heat may cause distortion or
other damage to non-metallic parts.
Maximum allowable inlet water pressure is
125 psi. If daytime pressure is over 80 psi,
night time pressure may exceed the maxi-
mum. Use a pressure reducing valve to
reduce the pressure.
Softener resins may degrade in the pres-
ence of chlorine or chloramines above 2
ppm. If there is chlorine or chloramines in
excess of this amount, it can reduce the
life of the resin. In these conditions, a car-
bon filter with a chlorine reducing media
may be considered. Contact US Water
Systems for Chlorine and Chloramine re-
moval equipment.
WARNING:
Discard all unused parts
and packaging material after installation.
Small parts remaining after the installation
could be a choke hazard.
Specifications
Model Number Tank
Size
Resin
Amount
Capacity Salt Needed for
Regeneration
Maximum
Flow Rate
Minimum
Flow Rate
091-EPWS-1
7X24 0.3 cu/ft
10,000
Grains
3lbs
3 GPM
1.4 GPM
091-EPWS-2
8X35 0.7 cu/ft
20,000
Grains
6 lbs
7 GPM
1.4 GPM
Continuous operation at flow rates greater than the service flow rate may affect capacity
and efficiency performance.
The manufacturer reserves the right to make product improvements which may deviate
from the specifications and descriptions stated herein, without obligation to change previ-
ously manufactured products or to note the change.
The above capacity and flow rate specifications have not been validated by WQA.