WATER PRESSURE: 

A minimum of 20 pounds of water pressure is required for re-

generation valve to operate effectively. 

ELECTRICAL FACILITIES: 

An uninterrupted alternating current (A/C) supply is 

required. Please make sure the voltage supply is compatible with the unit before instal-

lation. 

EXISTING PLUMBING: 

Condition of existing plumbing should be free from lime 

and iron buildup. Piping that is built up heavily with lime and/or iron should be replaced.  

LOCATION OF AQUATROL TANK AND DRAIN: 

The Aquatrol tank should be locat-

ed close to a drain to prevent air breaks and back flow. 

BY-PASS VALVES: 

Always provide for the installation of a by-pass valve if unit is not 

equipped with one.  The Catalytic Carbon Aquatrol is equipped with a bypass valve. 

CAUTION: 

Water pressure is not to exceed 80 psi, water temperature is not to exceed 

110°F (43°C), and the unit cannot be subjected to freezing conditions or direct sunlight. 

 

1) Use a piece of duct tape to cover the top of the distributor tube in the tank.  Be sure the 

distributor tube is centered in the tank.  The distributor tube should be flush with the top of 

the tank or no more than 1/4” below flush.  Install the supplied funnel and pour the 

gravel

 

in the tank 

first

.  Each system will ship with gravel and Catalytic Carbon media.  Pour the 

gravel in the tank first then pour in 

all

 the Catalytic Carbon media that was shipped in the 

tank last.  US Water does not ship “extra” media.   

    

 

 

 

 

 

 

 

 

 

 

 

 

Aquatrol Installation Instructions and Specifications 

Aquatrol Tank and Control Valve Preparation 

Installation, Operation and Maintenance Manual 

 

AQF-CX-100 & AQF-CX-200     

Содержание Aquatrol 075-AQF-CX

Страница 1: ...m REVISION 1 5 10 31 14 Owners Manual Models 075 AQF CX US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Vis...

Страница 2: ...ping damage within 24 hours of de livery Claims made after 24 hours may not be honored Small parts needed to install the system are in a parts bag To avoid loss of the small parts keep them in the par...

Страница 3: ...may exceed the maxi mum Use a pressure reducing valve to re duce the pressure WARNING Discard all unused parts and packaging material after installation Small parts remaining after the installation c...

Страница 4: ...tic Carbon Aquatrol is equipped with a bypass valve CAUTION Water pressure is not to exceed 80 psi water temperature is not to exceed 110 F 43 C and the unit cannot be subjected to freezing conditions...

Страница 5: ...pper basket over the distributor tube and push the valve on the tank Thread the valve on the tank by turning it clockwise Be sure not to cross thread the valve on the tank Tighten the valve hand tight...

Страница 6: ...ould be used to seal the threads when the plumbing is attached The inlet and outlet can be identified on the bypass valve There are arrows stamped in the bypass valve showing flow direction The arrow...

Страница 7: ...the control valve Be sure to use a hose clamp to secure the drain line to the barbed fitting on the control valve Aquatrol Carbon Tank Installation Instructions Installation Operation and Maintenance...

Страница 8: ...ramming mode DOWN UP Increase or decrease the value of the settings while in the programming mode IMMEDIATE REGENERATION To start an immediate regeneration press and hold the Cycle button Button for 3...

Страница 9: ...ton simultaneously to enter into Programing Mode Press Up or Down buttons to change hours Press the Settings Button to accept and continue 11 30 11 30 Press Up or Down buttons to change minutes Press...

Страница 10: ...g Choose Between Time Meter Immediate or Meter Delayed Meter immediately Meter Delay 11 30 Type T 11 30 Type m 11 30 Type TM Time Clock Delayed Control A Time Clock Delayed Control regenerates the sys...

Страница 11: ...ault 2 00 a m OFF Hours Override range Every 24 hours Set to 168 or to the interval dis cussed with your Certified Water Specialist Use UP or DOWN Buttons to adjust the Regeneration Time Flashing Flas...

Страница 12: ...ng Default setting is 015 Press the Setting Button to accept and continue to next digit 11 30 Set 5 bw Flashing Flashing Flashing Fourth Step Setting the Back Wash Time Use UP or DOWN Buttons to chang...

Страница 13: ...t setting is 060 Press the Setting Button to accept and continue to next digit Flashing Flashing Flashing Fifth Step Setting the Brine Time Use UP or DOWN Buttons to change Brine time minutes To 0 Thi...

Страница 14: ...Default setting is 010 Press the Setting Button to accept and continue to next digit Flashing Flashing Flashing Seventh Step Setting the Rapid Rinse Time Use UP or DOWN Buttons to change Rapid Rinse...

Страница 15: ...ting is 012 Press the Setting Button to accept and continue to next digit Flashing Flashing Flashing Eighth Step Setting the Brine Fill Time Use UP or DOWN Buttons to change Brine Fill time 0 minutes...

Страница 16: ...lly then allow water to run to drain for the entire backwash cycle or until all media fines are washed out of the filter indicated by clear water coming from the drain hose 5 The valve will automatica...

Страница 17: ...NOT BE LIABLE FOR ANY INCIDENTIAL OR CONSEQUENTIAL DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU TH...

Отзывы: