background image

 

 

 

Proper Installation 

This water filtering system must be properly installed and located in accordance with the 
Installation Instructions before it is used or the warranty will be void. 

 

Do not  

install or store where the system 

will be exposed to temperatures below 
freezing or exposed to any type of weather.  
Water freezing in the system will break it. 
Do not attempt to treat water over 100°F. 

 

Do not 

install in direct sunlight.  Exces-

sive sun or heat may cause distortion or 
other damage to non-metallic parts. 

 

Properly ground to conform with all govern-
ing codes and ordinances. 

 

Use only 

lead-free solder and flux 

for all 

sweat-solder connections, as required by 
state and federal codes. 

 

Maximum allowable inlet water pressure is 
80 psi.  If daytime pressure is over 60 psi, 
night time pressure may exceed the maxi-
mum.  Use a pressure reducing valve to re-
duce the pressure. 

 

WARNING: 

Discard all unused parts and 

packaging material after installation. Small 
parts remaining after the installation could 
be a choke hazard. 

The Aquatrol system provides Chlorine and Chloramine removal throughout the home. The 
Aquatrol system should be installed at the point of entry to treat the entire home, both hot and 
cold water. 
 
The Catalytic Carbon media in the Aquatrol system tank provides filtration when the system is 
in service to collect contaminants.  These contaminants are backwashed from the media 
surface when the system regenerates/backwashes.   
 
 

Aquatrol Oxi-Gen Benefits 

 

Chlorine and Chloramine Removal 

 

Virtually maintenance free.  

 

Improves the efficiency of water-using appliances 

 

Simple installation 

 

Safe for landscaping and lawn watering. 

 

Compatible with all on-site and community wastewater treatment systems 

Introduction 

Installation, Operation and Maintenance Manual 

 

AQF-CX-100 & AQF-CX-200     

Содержание Aquatrol 075-AQF-CX

Страница 1: ...m REVISION 1 5 10 31 14 Owners Manual Models 075 AQF CX US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Vis...

Страница 2: ...ping damage within 24 hours of de livery Claims made after 24 hours may not be honored Small parts needed to install the system are in a parts bag To avoid loss of the small parts keep them in the par...

Страница 3: ...may exceed the maxi mum Use a pressure reducing valve to re duce the pressure WARNING Discard all unused parts and packaging material after installation Small parts remaining after the installation c...

Страница 4: ...tic Carbon Aquatrol is equipped with a bypass valve CAUTION Water pressure is not to exceed 80 psi water temperature is not to exceed 110 F 43 C and the unit cannot be subjected to freezing conditions...

Страница 5: ...pper basket over the distributor tube and push the valve on the tank Thread the valve on the tank by turning it clockwise Be sure not to cross thread the valve on the tank Tighten the valve hand tight...

Страница 6: ...ould be used to seal the threads when the plumbing is attached The inlet and outlet can be identified on the bypass valve There are arrows stamped in the bypass valve showing flow direction The arrow...

Страница 7: ...the control valve Be sure to use a hose clamp to secure the drain line to the barbed fitting on the control valve Aquatrol Carbon Tank Installation Instructions Installation Operation and Maintenance...

Страница 8: ...ramming mode DOWN UP Increase or decrease the value of the settings while in the programming mode IMMEDIATE REGENERATION To start an immediate regeneration press and hold the Cycle button Button for 3...

Страница 9: ...ton simultaneously to enter into Programing Mode Press Up or Down buttons to change hours Press the Settings Button to accept and continue 11 30 11 30 Press Up or Down buttons to change minutes Press...

Страница 10: ...g Choose Between Time Meter Immediate or Meter Delayed Meter immediately Meter Delay 11 30 Type T 11 30 Type m 11 30 Type TM Time Clock Delayed Control A Time Clock Delayed Control regenerates the sys...

Страница 11: ...ault 2 00 a m OFF Hours Override range Every 24 hours Set to 168 or to the interval dis cussed with your Certified Water Specialist Use UP or DOWN Buttons to adjust the Regeneration Time Flashing Flas...

Страница 12: ...ng Default setting is 015 Press the Setting Button to accept and continue to next digit 11 30 Set 5 bw Flashing Flashing Flashing Fourth Step Setting the Back Wash Time Use UP or DOWN Buttons to chang...

Страница 13: ...t setting is 060 Press the Setting Button to accept and continue to next digit Flashing Flashing Flashing Fifth Step Setting the Brine Time Use UP or DOWN Buttons to change Brine time minutes To 0 Thi...

Страница 14: ...Default setting is 010 Press the Setting Button to accept and continue to next digit Flashing Flashing Flashing Seventh Step Setting the Rapid Rinse Time Use UP or DOWN Buttons to change Rapid Rinse...

Страница 15: ...ting is 012 Press the Setting Button to accept and continue to next digit Flashing Flashing Flashing Eighth Step Setting the Brine Fill Time Use UP or DOWN Buttons to change Brine Fill time 0 minutes...

Страница 16: ...lly then allow water to run to drain for the entire backwash cycle or until all media fines are washed out of the filter indicated by clear water coming from the drain hose 5 The valve will automatica...

Страница 17: ...NOT BE LIABLE FOR ANY INCIDENTIAL OR CONSEQUENTIAL DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU TH...

Отзывы: