Installation Instructions
Residential Reverse Osmosis Drinking Water System
Page 5
NOTE: All plumbing must be completed in accordance
with state and local plumbing codes. Some
municipalities may require the installation be
performed by a licensed plumber. Check your local
authority prior to installation.
A. Faucet installation
If the sink has a sprayer it may be disconnected for
faucet installation. A pipe cap or plug will be
necessary to seal the sprayer connection. To make
the faucet mounting hole (if sprayer or second hole is not
used), check below to make sure the drill does not
interfere with anything below. Drill a 7/8” minimum 1 1/8”
maximum hole for air gap faucet installations and a 7/16’
hole for non-air gap faucets. Be sure to use a bit
compatible with your surface. Clean up sharp edges.
The faucet should be positioned so it empties into
the sink and the spout swivels freely for
convenience. If sink has a hole that can
accommodate the RO faucet, no drilling is required.
Proceed with mounting the faucet.
FEED WATER CONNECTION
is accomplished with an angle stop feed water valve. This valve will be installed in
the cold water line between the sink cold water shutoff valve and the sink faucet tubing. Connect to a potable, cold wa-
ter supply line only.
NOTE:
Softened water is preferred since it will extend the life of your R/O membrane.
DRAIN CONNECTION
is accomplished using a waste water saddle valve which is designed to fit around a standard
1-1/2” OD drain pipe. The drain saddle valve should always be installed above (before) the trap and on the vertical or
horizontal tailpiece.
Do not install the drain saddle valve near a garbage disposal; otherwise, plugging of the waste water line may occur. If dis-
charging into a utility sink or standpipe, an air gap may be needed. (Air gaps must be 1” or greater above the floor or pipe
rim). US Water offers other drain line connection options on www.uswatersystems.com
NOTE:
Plumbing codes may require the use air gaps. Please check with your local municipality.
Do not connect the R/O system drain line to the dishwasher drain line due to the fact back pressures may cause the air
gap to overflow.
RO System Installation Procedure