Installation Instructions
Residential Reverse Osmosis Drinking Water System
Page 14
2.
BE SURE
the storage tank shutoff valve is in the closed
position. Use the supplied syringe and add 5ml of the
supplied sanitizing solution to the Green tank tubing
attached to the storage tank. Connect the open end of the
green tubing from tank to RO unit at the post carbon filter
inlet tee fitting. Leave the tank valve closed.
3. Connect orange tubing from the angle stop supply valve to
RO unit at the sediment filter inlet fitting.
Permeate Pump Installation
If the system is equipped with a permeate pump, clip the pump
to the membrane housing using the supplied mounting bracket
and make the connections to the pump using the label on the
pump and the labels on the tubing. There will be a Permeate
IN, Permeate OUT and Brine IN connection on the pump.
The Brine OUT connection will be made in the following step.
4. Connect the tubing from the drain saddle to the RO unit at
the flow restrictor on the membrane on a standard system
or on the “Brine Out” port on a permeate pump system. If
the air gap is being used, connect the black 1/4” line from
the faucet to the flow restrictor or to the “brine out” port on
the permeate pump.