Softener Preparation
Focus Tank Installation Instructions
WATER PRESSURE:
A minimum of 20 pounds of water pressure is required for regeneration valve to oper-
ate effectively.
ELECTRICAL FACILITIES:
An uninterrupted alternating current (A/C) supply is required. Please make sure
your voltage supply is compatible with your unit before installation.
EXISTING PLUMBING:
Condition of existing plumbing should be free from lime and iron buildup. Piping
that is built up heavily with lime and/or iron should be replaced.
LOCATION OF FOCUS TANK AND DRAIN:
The Infusion tank should be located close to a drain to prevent
air breaks and back flow.
CAUTION:
Water pressure is not to exceed 80 psi, water temperature is not to exceed 110°F (43°C), and
the unit cannot be subjected to freezing conditions.
Media Installation
1) Remove the resin tank from carton.
2) Verify the riser tube is centered in the bottom center of the tank. A flashlight may be
necessary. There is an indentation in the bottom of the tank that will center the dis-
tributor tube. The distributor tube should be flush with the top of the tank when it is
installed properly.