15
System Start-Up
Key Pad Configuration
Start-up Instructions
“GEAR”
This function is to enter the programing mode
required at the time of installation. This button
serves as the “Save” button.
REGEN
“Triangle
Arrows”
This function is to initiate a regeneration. This
button also unlocks each parameter to be
changed in the programming mode.
DOWN / UP Increase or decrease the value of the settings
while in the programming mode.
IMMEDIATE REGENERATION
To start an immediate regeneration (or step
valve through each position), press and hold
the MANUAL REGEN. Button for 3 seconds
(until beeps). The valve will start an immedi-
ate regeneration. Press any key to skip to
the next cycle.
Manual Regeneration (Step / Cycle Valve)
1. Plug the power transformer into an ap-
proved power source. Connect the power
cord to the valve.
2. When power is supplied to the control, the
screen will display the time of day, gallons
remaining and the mode. Press and hold
the “Manual” regen button. The valve will
display “goto BW”. Once the valve stops
moving the valve
3. Once in the backwash (BW) cycle the dis-
play will show a time value (10), open the
inlet on the bypass valve slowly and allow
water to enter the unit. Allow all air to es-
cape from the unit before turning the by-
pass fully open. Then allow water to run to
drain for 3-4 minutes or until all media
fines are washed out of the softener indi-
cated by clear water in the drain hose.
4. When the backwash cycle is complete, the
valve will advance to the brine draw (BD)
position. Once the valve reaches the BD
cycle, push and release the “Regen” but-
ton. The display will show “goto
RR” (Rapid Rinse). Allow the system to
rinse to the drain. Allow the water to run
for the entire rinse cycle.
5. When the rinse cycle is complete, the
valve will advance to the REFILL position.
Check that the control valve is pushing wa-
ter into the brine tank (remove brine well
cap to confirm that the water level is rising
in the brine tank). Allow the valve to refill
for the full amount of time as displayed on
the screen to insure a proper brine solution
for the next regeneration.
6. The valve will automatically advance to the
SERVICE position. Open the outlet valve
on the bypass, then open the nearest
treated water faucet and allow the water to
run until clear, close the tap and replace
the faucet screen.
7. Program unit.