-7-
VENT TERMINATION CLEARANCES
A.
Minimum 4-foot (1.22m) clearance below or beside any door or window that opens.
B. Minimum 1-foot (0.3m) clearance above any door or window that opens.
C.
Minimum 3-foot (0.91m) clearance from any adjacent building.
D.
Minimum 7-foot (2.13m) clearance from any grade when adjacent to public walkways.
E. Minimum 2-foot (0.61m) clearance above any grass, plants, or other combustible materials.
F.
Minimum 3-foot (0.91m) clearance from an forced air intake of any appliance.
G.
Minimum 2-foot (0.61m) clearance below eves or overhang.
H. Minimum 1-foot (0.3m) clearance horizontally from combustible wall.
I.
Must be a minimum of 3 foot (0.91m) above the roof and 2 foot (0.61m) above the highest point or the roof
within 10 feet (3.05m).
VENT TERMINATION
CLEARANCES
Installation
G
Содержание Ashley AP5780
Страница 27: ...27 Wiring Diagram 1 25A 250V FUSE 7 5A 250V FUSE...
Страница 28: ...Notes...
Страница 34: ...27 1 25A 250V Fusible 7 5A 250V Fusible Sch ma De C blage...