35
Error: PRNDL Signal Low
Sensor voltage is low.
Error: PRNDL Signal High
Sensor voltage is high.
Error: No PRNDL PWM Signal
Connect the controller to a PC and use Shiftware to reload the calibration using
a 4R70W calibration.
Error: Invalid PRNDL Code=XX-XX
DTR or PSM signal combination not valid. XX-XX indicates high/low status of all
4 DTR pins (1 or 0)
Error: Ford DTR Voltage too Low
Voltage from 270 Ohm resistor in Ford DTR sensor measures too low.
Error: Ford DTR Voltage too High
Voltage from 270 Ohm resistor in Ford DTR sensor measures too high.
Low-Side Driver Shorted
A low-side output driver appeared to be shorted on during power-on solenoid
check. Contact Baumann Electronic Controls technical support for assistance.