26
OIL LEAKS
Defective oil pressure gauge. Replace gauge.
LOW OIL PRESSURE
Oil foaming in crankcase. Drain existing lu-
bricant, thoroughly clean crankcase, replace
lubricant.
Debris or other obstruction blocking oil flow.
Inspect/clean all oil passages.
EXCESSIVE OIL PRESSURE FLUCTUATIONS
(LESS THAN 5 PSI)
Oil foaming in crankcase. Drain existing lu-
bricant, thoroughly clean crankcase, replace
lubricant.
Debris or other obstruction blocking oil flow.
Inspect/clean all oil passages.
TROUBLE SHOOTING:
ELECTRIC DRAINING
VALVE WILL NOT CLOSE
Debris in solenoid valve prevents diaphragm
from seating. Remove solenoid valve, disas-
semble, clean and reassemble.
Short in electrical component. Check and re-
place power cord or timer as needed.
TIMER WILL NOT ACTIVATE
No electrical supply. Apply power.
Timer malfunction. Replace timer.
Clogged port. Clean valve.
Solenoid valve malfunction. Replace solenoid
valve.
Clogged strainer. Clean strainer.
TECHNICAL DATA
COMP9503
COMP9505
COMP9510
COMP9515
VOLTAGE-FREQUENCY
TANK CAPACITY
VOLUME AT 90 PSI
VOLUME AT 150 PSI
MAXIMUM PRESSURE
STAGES
POWER
WEIGHT
(220 - 440) V ~ 60 Hz
300 L
22 CFM
18 CFM
175 PSI
1
5 HP
190 kg (418,8 lb)
VOLTAGE-FREQUENCY
TANK CAPACITY
VOLUME AT 90 PSI
VOLUME AT 150 PSI
MAXIMUM PRESSURE
STAGES
POWER
WEIGHT
(220 - 440) V ~ 60 Hz
500 L
22 CFM
18 CFM
175 PSI
1
5 HP
300 kg (661,3 lb)
VOLTAGE-FREQUENCY
TANK CAPACITY
VOLUME AT 90 PSI
VOLUME AT 150 PSI
MAXIMUM PRESSURE
STAGES
POWER
WEIGHT
(220 - 440) V ~ 60 Hz
500 L
35 CFM
30 CFM
175 PSI
2
10 HP
350 kg (771,6 lb)
VOLTAGE-FREQUENCY
TANK CAPACITY
VOLUME AT 90 PSI
VOLUME AT 150 PSI
MAXIMUM PRESSURE
STAGES
POWER
WEIGHT
(220 - 440) V ~ 60 Hz
500 L
56 CFM
40 CFM
175 PSI
2
15 HP
380 kg (837,7 lb)