urmet domus elekta Скачать руководство пользователя страница 12

12 

−−−−

 

sec.3g

2 VOICE - Technical Manual

ELEKTA AND ELEKTA STEEL CALL MODULE

DOOR OPENER

The second level DOOR OPENER code can be used to con

fi

 gure 

up to 100 door codes which are not linked to any name or physical 

code. These codes may be used by maintenance personnel, for 

instance.

The menu can be used to add new codes, edit exiting codes and 

delete one or all codes from the database.

Select DOOR OPENER from the main 

menu. The menu shown here by the side 

will appear. Select the required function 

with the 

 

buttons and press 

OK

 to 

con

fi

 rm.

New

Enter the new DOOR CODE using the 

keypad and press 

OK

 to con

fi

 rm.  The 

code must be four digits long (permitted 

values: 0001 ÷ 9999).

Press 

C

 on the short-cut menu to enter 

the digit to the left of the cursor if you 

make a mistake. The cursor can be 

moved onto the numeric string using the  

 and 

 

buttons.

The page shown here by the side will 

appear and the keypad will be deactivated 

for approximately three seconds if a code 

which is already present is con

fi

 rmed.

The page shown here by the side will 

appear and the keypad will be deactivated 

for approximately three seconds if the 

code length is incorrect.

The new code will be added to the 

database and the system will go back to 

the DOOR OPENER menu.

Modify

Select a code to be edited with the 

 

buttons and press 

OK

 to con

fi

 rm.

The procedure is the same as that 

described for adding new codes.

Delete

Select a code to be deleted with the 

 

buttons and press 

OK

 to con

fi

 rm.

Press 

OK

 to con

fi

 rm deletion or press 

X

 

to cancel it.

IMPORTANT:

 The deletion operation 

cannot be undone.

Delete all

Press 

OK

 to delete all door codes or 

press 

X

 to cancel the operation.

IMPORTANT:

 The deletion operation 

cannot be undone.

KEYS (function available only for models 1083/15 and 1083/16)

The second level KEYS menu can be used to acquire new 

transponder keys and delete one or all keys acquired by the calling 

module.

Select KEYS on the main menu. The 

menu shown here by the side will appear. 

Select the required function with the 

 

buttons and press 

OK

 to con

fi

 rm.

2VOICE ELEKTA CALL MODULE Ref. 1083/15 (50Hz) – 1083/25 (60Hz)

2VOICE ELEKTA STEEL CALL MODULE Ref. 1083/16 (50Hz) – 1083/27 (60Hz)

PROGRAMMING

Содержание elekta

Страница 1: ...ION OF TERMINALS 4 PROGRAMMING 4 Menu structure 4 Default configuration 4 Parameter configuration 5 Programming procedure 6 Bluetooth programming 13 SECTION FOR USERS HOW TO USE THE CALLING MODULE 14...

Страница 2: ...door Unrestricted free or privacy electrical lock management Audio repeat device control for use with hearing aid optional Mail delivery function direct opening of pedestrian door by pressing the T or...

Страница 3: ...ng module with the finishing frame which is fixed using two Torx screws INSTALLATION Ref 1083 16 1083 27 Arrange the duct so that it ends at the lower hole of the flush mounting box Remove the lower c...

Страница 4: ...50Hz 1083 27 60Hz VOLUME ADJUSTMENT DESCRIPTION OF TERMINALS PROGRAMMING PROGRAMMING MENU STRUCTURE CODE TYPE AUTOMATIC FIT BUSY TIME STOPPABLE DOOR LOCK RELEASE TIME 1 OPEN DOOR 1 DOOR LOCK RELEASE T...

Страница 5: ...NO Door lock release type and time The door unit lock release type and lock output activation time The type may be SECRET pressing the door opener button on an apartment station will activate the door...

Страница 6: ...display Contact Urmet Customer Care and read the SERVICE CODE The Urmet operator will supply a temporary password PT IMPORTANT The PT you will be given can be used to access configuration until the ca...

Страница 7: ...to confirm See the Parameter table for more information on PHYSYCAL and LOGICAL mode The AUTOMATIC FIT function automatically replaces physical codes with sequential logical codes from 1 to 127 accord...

Страница 8: ...ling module must generate a feedback tone when a button is pressed using the buttons and press OK to confirm Enter the physical code of the extension where to route the call generated by pressing at l...

Страница 9: ...d to the SE SE terminals and to the C NC NO relay contacts by pressing the T or P button in the short cut menu of the calling module The time slots during which the postman function is activated can b...

Страница 10: ...New Enter the new NAME using the keypad special characters can be added like on a mobile phone by pressing buttons 1 and 0 and press OK to confirm the entered name The name may be up to 32 characters...

Страница 11: ...required It is not necessary to pair each name to a door code but it is not possible to allocate the same code to different names Press C on the short cut menu to enter the digit to the left of the cu...

Страница 12: ...esent is confirmed The page shown here by the side will appear and the keypad will be deactivated for approximately three seconds if the code length is incorrect The new code will be added to the data...

Страница 13: ...press OK to confirm Press OK to confirm the reset operation or X to cancel and go back to the main menu BLUETOOTH PROGRAMMING The calling module can be programmed directly or alternatively using a per...

Страница 14: ...ning an error message will appear for two seconds if an incorrect code is entered A confirmation message will appear on the display The warning message shown by the side will appear if the line is bus...

Страница 15: ...meric string using the and buttons Press the X button to go back to the home page A page containing an error message will appear for two seconds if an incorrect code is entered If the code inserted is...

Страница 16: ...tation to start an audio video conversation Press X to end the communication on the calling module and go back to the main page SPECIAL CODES To send a special code press and hold the 0 key for at lea...

Страница 17: ...CKS menu described below The following screenshot shows an example of configuration for calling six blocks If the user wants to call a single block from the PRIMARY calling module the BLOCKS INTERVAL...

Страница 18: ...proximately three seconds This page appears if an attempt to assign a name which was previously used for another block is made The system will automatically go back to the block modify page after appr...

Страница 19: ...OK to confirm the selection Key in the number of the apartment to be called using the numeric keypad and press the or OK button to confirm Select the block to which the apartment to be called belongs...

Страница 20: ...20 sec 3g 2 VOICE Technical Manual ELEKTA AND ELEKTA STEEL CALL MODULE...

Отзывы: