Emergency Lowering
Figure 7.29 - Emergency Lowering
To check the emer gency low er ing: Raise the plat -
form and turn the en gine OFF at the ground con trol
box KEY SWITCH.
Op er ate the emer gency lower by pull ing on the ca -
ble
(see Fig ure 7.29) lo cated at the front of the
chas sis. When the plat form is fully low ered re lease
the ca ble.
■
RCD / ELCB (Option)
Figure 7.30 - RCD / ELCB
The RCD (Re sid ual Cur rent De vice) is lo cated at
the ground and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat
form
outlet.
To re set the out let dis con nect the power tool lead
from the plat form box and re set the RCD at the
ground.
If the prob lem per sists call a trained ser vice tech ni -
cian.
■
Safety prop
Figure 7.31 - Safety Prop
In spect the safety prop(s) to see that it is pres ent
and moves freely.
■
Lanyard Anchorages (Option)
Check all four lan yard an chor ages on the floor of
the plat form to see that they are pres ent, not de -
formed, that they move freely, and that they are se -
curely at tached to the plat form.
■
Non-Slip Tread Grip
Figure 7.32 - Non-Slip Grip Strip
Check that the non-slip pro tec tive strip is in place
and in good con di tion
page 7 - 8
Rev A
SR3370 & SR2770 – 13184A