Área Industrial La Dehesa
Calle Dehesa Vieja, 2
28052 Madrid (España)
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]
08
Condition
Protect
ALM
100 ~
76%
75 ~
51%
50 ~
26%
25 ~
0%
Description
Turn Off
Power Off
Turn On
Idle
Charge
Float Charge
Discharge
Soft Start
Alarm
Protection
All LED lighting until battery is Off.
Flash once.
Current ≤ ± 0.1A; Only current SOC status LED slowly flash.
Only current SOC status LED constant lighting on.
SOC ≥ 99%, 0.1A ≤ Current ≤ 0.5A; Highest SOC status LED
constant lighting on, rest SOC LEDs flash per sec.
Residual SOC LEDs flash per sec.
All SOC LEDs constant lighting on, pre-charge circuit is working.
Alarm: Over Voltage, Low Voltage, Cell High / Low Temperature,
MOS high temperature, high current.
Charge MOS OFF.
Possible reason: charging over current 1/2; Over Voltage.
Discharge MOS OFF.
Possible reason: discharging over current 1/2; Low Voltage;
Short circuit; Reverse connected.
Charge and discharge MOS all OFF.
Possible reason: Over / Low Temperature;
MOS Over Temperature; i2c error.
Internal communication error,
Address assignment error.
Critical Failure:
MOSFAIL; FUSE broken.
_
_
_
_
_
_
100-76% 75-51%
50-26% 25-0%
_
_
_
_
Low SOC (SOC ≤ 10% or single cell voltage ≤ 3V).
Show SOC
1
: flash 1.5s Off / 0.5s On
/ / : flash 1s Off / 1s On
/ / : constant lighting
ADD Switch
ADD Switch: 4 ADD switches,
Dip1
to definite different baud rate (“0” is 115200, “1” is 9600).
“0”and “1”, refer to picture right. “0XXX” setup the baud rate 115200, and “1XXX” setup the baud rate 9600.
The settings will be active only after restart the battery.
Using RS485: all batteries need to set the ADD switch. And should be the same.
Using CAN: the ADD switch has no influence on CAN baud rate.
0
ecoline
www.masterbattery.es/en
UE-24Li2900WH
_
_