9
Single-stage SetPoint Controller Installation & Operation Manual
Thermostat Wiring
Zone Valve
-----------------------------------------------
Zone Control Module A3031003/A3031004
------------------------
Relay
---------------------------------------------------
C
518
R
Rh W1 S1
Com
No Power
C
R
Rh W1 S1
Com
No Power
Zone
Valve
24 V (ac)
Transformer
L N
R C
Floor Sensor (A3040079)
C
518
R
Rh W1 S1
Com
No Power
C
518
R
Rh W1 S1
Com
No Power
2
4
3
C
R
Rh W1 S1
Com
No Power
Floor Sensor (A3040079)
Zone Control Module
A3031003/A3031004
Install field
jumper wire
R to Rh
C
518
R
Rh W1 S1
Com
No Power
R C
2
1
8
7
3
4
5
6
C
R
Rh W1 S1
Com
No Power
L
N G
115 V (ac)
Floor Sensor (A3040079)
Relay
Transformer
Install field
jumper wire
R to Rh
Install field
jumper wire
R to Rh