5
Single-stage SetPoint Controller Installation & Operation Manual
Thick Floor Coverings [greater than
3
⁄
8
" (10mm)]
If installing a thick floor covering directly to the subfloor, a groove
1
⁄
8
" (4mm) wide by
1
⁄
16
"
(2mm) deep can be cut into the back of the flooring material to accommodate the wire for
the sensor. Ensure the sensor is located in such a position that the attached wire is able to
reach to a suitable junction location.
Avoid splices under the floor covering to ensure
trouble-free operation. Cut a groove
3
⁄
16
" (5mm)
wide by
3
⁄
16
" (5mm) deep by 1
3
⁄
4
" (45mm) long to
accommodate the sensor. Locate the sensor midway
between the heating elements to ensure a proper
temperature reading.
Note:
If it is not practical to cut a groove in the
surface covering, follow the installation method used
for thin floor coverings.
Floor Sensor Installation
Thin-set or Thin-pour Applications
If installing the floor covering over either a thin-set or thin-pour material of sufficient depth,
the floor sensor can be placed directly into either the thin-set material or the thin-pour
material and covered over. Ensure the sensor is
located in such a position that the attached wire is
able to reach to a suitable junction location. Avoid
splices within the thin set or thin pour to ensure
trouble-free operation. Locate the sensor midway
between the heating elements to ensure a proper
temperature reading.
Tiles
Thin Set
Hydronic
Pipe
Thin Floor Coverings [less than
3
⁄
8
" (10mm)]
If installling a thin floor covering directly to the subfloor, a groove
1
⁄
8
" (4mm) wide by
1
⁄
16
"
(2mm) deep can be cut into the surface of the subfloor to accommodate the wire for the
sensor. Ensure the sensor is located in such a position that the attached wire is able to reach
to a suitable junction location. Avoid splices under the floor covering to ensure trouble-free
operation. Cut a groove
3
⁄
16
" (5mm) wide by
3
⁄
16
"
(5mm) deep by 1
3
⁄
4
" (45mm) long to accommodate
the sensor. Locate the sensor midway between the
heating elements to ensure a proper temperature
reading.
Hardwood
Subfloor
Hardwood
Subfloor
New Installations
------------------------------------------