UPM THM501 Скачать руководство пользователя страница 21

PROBLEM

SOLUTION

Heat will not come on but the
 symbol is animated.

Air conditioning will not come on.

Air conditioning will not come on 
but the        symbol is animated.

Thermostat turns the heating / 
cooling systems on before my 
programmed set times.

Heating system seems to cycle 
too often.

1) Check if the furnace switch and/or pilot flame is turned on, as it may have been turned off.
2) Allow several minutes for the heating system to heat up and the fan to activate.  Most heaters will heat  
    up the system for a short while before warm air can be ventilated by the fan.  Also check that the 
    HE/HG setting is set correctly.  (Refer to page 16).
3) If the heat still does not come on, check the wiring installation again.  (Refer to pages 28 and 29).

1) Check and ensure that the thermostat is set to the COOL or AUTO mode.
2) Check and ensure that the set temperature is 

lower

 than the current (room) temperature.

3) You may have to wait up to 5 minutes before the air conditioning will turn on.  The thermostat has a 
    built-in time delay to protect the air conditioner compressor from undesirable on/off sequences.
4) After a 5-minute wait, the air conditioning should now be on.  Whenever  the cooling system is 
    running, the        symbol will be animated.

1) Check if the air conditioning system’s main switch is turned on, as it may have been turned off.
2) Wait several minutes for the air conditioning system to activate.  If the air conditioning still does not 
    come on, check the wiring installation again.  (Refer to pages 28 and 29).

- This is normal if the Pre-comfort Recovery system is enabled.  The Pre-comfort Recovery will activate 
the heating/cooling in advance of the actual programmed set time so that the room will be at the desired 
temperature at the start of the comfort program time.  You may disable this feature in the optional 
settings.  (Refer to page 16).

- Check and ensure that you have selected a Cycle Rate that matches your particular heating system.
  (Refer to page 15).  The default is set at Cr-3 for gas or oil forced air systems.  If you find it still cycling
  too often, you may wish to try a slower cycle rate or disable the cycling.  When disabled, the 
  thermostat will operate at a fixed span of ±0.5°C (±1.0°F).  For example, if the programmed 
  temperature is set at 20°C (68°F), the thermostat will turn the heat on if the current (room) temperature
  falls below 19.5°C (67°F) and turn the heat off when the current (room) temperature reaches 20.5°C 
  (69°F).

19

Содержание THM501

Страница 1: ...PROGRAMMABLE THERMOSTAT THM501 http waterheatertimer org Woods timers and manuals old html Noma Garrison...

Страница 2: ...LEAVE BLANK...

Страница 3: ...rfaces with humidifier for automatic humidity control Interfaces with heating air conditioning systems for automatic temperature control Automatic change over for HEATING COOLING programs Copy 1 day s...

Страница 4: ...e LOCK key press and release the RESET R key located above the battery compartment on the back The LCD screen will blank out momentarily The default temperature scale is Celsius C The temperature disp...

Страница 5: ...e scale C or F CANNOT be changed afterwards unless you perform another HARD RESET on the thermostat REFER TO PAGES 17 and 31 Pull apart firmly to remove the back cover from the thermostat DO NOT try t...

Страница 6: ...AHEAD PROGRAM SET CLOCK OPTION HOLD BACK FAN COPY WEEKDAY USAGE MODE HOME UP DOWN LOCK Function Key Descriptions 4...

Страница 7: ...ION SET OPTIONS COPY PROGRAM LCD Display 5 OVERRIDE INDICATION PROGRAM NUMBER Press SET CLOCK to start time setting The time and SET symbol will flash Use AHEAD or BACK to set the current time Press S...

Страница 8: ...me The setting can be adjusted to minimize energy consumption This is for the time you return home and want the house at a comfortable temperature typically warmer settings during winter and cooler se...

Страница 9: ...t in increments of 0 5 The setpoint temperature range is 5 C to 32 C 41 F to 89 F for heating After setting the desired time and temperature for P1 press PROGRAM again to display P2 Again use AHEAD or...

Страница 10: ...OWN key to change the numbers quickly Copy Program Function This thermostat can copy program settings from one day to another using the COPY key Make sure the thermostat is engaged in the program sett...

Страница 11: ...o hold the thermostat at a constant temperature and disable all set programs until released Press HOLD once and use UP or DOWN button to set the desired hold temperature The HOLD symbol will appear to...

Страница 12: ...AM at any time to scroll through and check all other programs Press HOME to return to the normal display Room Temperature Current room temperature is displayed on the mid section of the LCD screen Rel...

Страница 13: ...5 To turn the humidifier OFF press DOWN until OFF appears Press SET CLOCK to exit The humidifier will turn on if the relative humidity is lower than the set humidity level The humidity level can be s...

Страница 14: ...Approximately 2 hours ago the temperature was about 19 C 66 F Approximately 3 hours ago the temperature was about 18 C 64 F Approximately 7 hours ago the temperature was about 22 C 72 F Approximately...

Страница 15: ...15 and 16 Usage Monitor The thermostat tracks the system ON time the time the heating cooling equipment is running Press USAGE once to view USAGE TODAY Press USAGE again to view USAGE THIS WEEK USAGE...

Страница 16: ...AUTO OFF Mode Press MODE to toggle between the modes If the thermostat is in the OFF mode both the heating and cooling systems will be turned off and all programs and settings will be disabled To cont...

Страница 17: ...by pressing UP or DOWN See Chart 1 Chart 1 Cr Cr 0 Cr 1 Cr 2 Cr 3 Cr 4 System disabled 2 3 5 7 Cycles per hour Commercial Unit Hydronic heat condensing gas furnaces Gas or oil forced air default Elec...

Страница 18: ...hange the LCD contrast with this option Choose from CO 0 to CO 9 by pressing UP or DOWN CO 0 lowest contrast CO 9 highest contrast HE Use this setting for electric heating systems With this setting th...

Страница 19: ...the set programs and thermostat settings if ever the batteries go completely dead or if the batteries are removed from the thermostat for an extended period of time When the batteries are re inserted...

Страница 20: ...SET R key on the back of the thermostat above the battery compartment This is an indication that the batteries are running low Replace with fresh alkaline batteries Note We recommend to have the batte...

Страница 21: ...wait the air conditioning should now be on Whenever the cooling system is running the symbol will be animated 1 Check if the air conditioning system s main switch is turned on as it may have been turn...

Страница 22: ...of one another The COOL temperature setting will always be at least 3 C 6 F higher than the HEAT temperature setting For example if the initial COOL program temperature was set at 24 C 75 F and you de...

Страница 23: ...Installation Guide 21...

Страница 24: ...y chart for more details Monday Tuesday Wednesday Thursday Friday Saturday Sunday programming with 4 settings per day Display temperature with 0 1 resolution 2 AA size batteries required included Buil...

Страница 25: ...Pump Multi Stage equipment Compatible with Thermostat Yes Yes Yes Yes Yes Some models Some models No No Yes Compatibility Generally equipment with low voltage control is compatible with the Heating C...

Страница 26: ...arily and labeling the disconnected wires Power drill with a 3 16 bit If necessary to drill holes on the wall screwdriver Installation The following tools may be required for installation See below to...

Страница 27: ...ide wall or next to a door leading outside Exposed to direct light or heat from a lamp sun fireplace or other temperature radiating objects which may cause false readings Near or in direct airflow fro...

Страница 28: ...structions and receipt Remove cover from old thermostat If it does not snap off when pulled firmly from the bottom check for a screw used to secure the cover Loosen screws holding thermostat to the wa...

Страница 29: ...r horizontally on the wall Select two appropriate mounting holes and mark the locations with a pencil If necessary use a level to make sure the thermostat is leveled Remove the back cover from the wal...

Страница 30: ...ostat If you have two R wires then connect each wire to its corresponding terminal and remove the JUMPER between the RC and RH terminals If you have a C wire connect it to the C terminal This allows t...

Страница 31: ...2 WIRE HEATING Wiring Diagram 3 WIRE HEATING 4 WIRE HEATING COOLING 5 WIRE HEATING COOLING 29...

Страница 32: ...e original humidistat needs to be connected to the 2 terminals marked H1 and H2 on the thermostat The original humidistat should be removed or set to OFF position Noted The 2 humidifier control termin...

Страница 33: ...D reset and select C or F first press and hold the LOCK key While holding down the LOCK key press and release the RESET R key located above the battery compartment on the back The LCD screen will blan...

Страница 34: ...ive part s repaired or replaced free of charge within the stated warranty period when returned by the original purchaser with proof of purchase This product is not guaranteed against wear or breakage...

Отзывы: