Unisight Digital Technologies
The Relation tab allows you to configure any supported alarm relay controller that you
have connected to the Unisight DVR Server. To configure an individual sensor connected to
the alarm relay controller select the sensor from the Sensor list. Once the sensor is
highlighted select the
Sensor Property
button. The Sensor Property dialog box will appear.
(Fig. 2-13) Determine if your sensor is a high or low level trigger and select the appropriate
radio button. The ID field corresponds to which input you have your sensor connected to on
the alarm relay controller. Input the proper number in the ID field. Using the Description field,
you can give your sensors different names. Once you have your sensor configured select the
Ok
button to return to the Relation tab.
(Fig. 2-13)
You can link each individual sensor to any number of video channels or alarm outputs
on the alarm relay controller. To configure the alarm outputs select the output number that the
alarm device is connected to on the alarm relay controller by checking the box in Link To
Output. Enter a description and select either High or Low for the Trigger. You can also select
a High Level Pulse or a Low Level Pulse. The Pulse will trigger the output for a short time
and then turn off. You can link several alarm outputs to a single sensor. To link a sensor to a
video channel for recording select the sensor from the Sensor List. Then check the box next
to the desired video channel under the Link To Video Channel. The Preset column allows you
to enter a PTZ Preset Position number that the PTZ camera will automatically move to when
the sensor is triggered. The Snapshot column will allow you to save a snapshot when the
sensor is triggered. The Output column allows you to assign an alarm output number that will
trigger the corresponding alarm device connected to that specific output on the alarm relay
controller. The Matrix In column will display the video channel number that is entered on
Public View 01.
Guard Schedule Tab
The Guard Schedule tab is where you configure the schedule for each sensor
connected to the alarm relay controller. Unless a schedule is set and activated, the sensor(s)
attached to the alarm relay controller will be disabled. Refer to the Schedule Tab section for
setup.
20