Hot Water Boiler with Steel Body, Automatic Fuel Feed Operation and Maintenance Manual
boiler is connected to an old installation, it is necessary to clean the waste completely before
installation. The installation must be cleaned and cleaned several times.
Avoid overloading fuel into the boiler and check the suitability of the supply - standby settings given
in the operating instructions. These settings, which indicate the working and stopping time of the
gear unit, are the chimney characteristics of the boiler (traction difference, etc.), ambient conditions,
thermal comfort need of the space, insulation of the space etc. It depends on many parameters. The
settings given in the catalog are required when the boiler is required to operate at a lower power
than it is given to operate at maximum power; combustion must be observed. Adjusting the settings
to prevent the burning of the unburned coal down the ladle will be appropriate for both the boiler
efficiency and the economy.
Burning and floating fuel particles in the boiler, fuel ashes out of the open door can easily open to
the outside environment, the fan must not be opened while the fan is working. When the boiler is
burned, the covers must not be opened or manually loaded onto the hob or into the boiler.
The electrical connection must never be cut off while the boiler is operating.
For any reason, direct cold water should not be added to the overheated boiler for cooling. This can
cause noise in the installation, excessive thermal stresses in the boiler and thus permanent damage.
The water in the installation must not be drained unless there is a risk of maintenance or freezing.
The system design should ensure that the ratio between the water flow rate and the boiler capacity
is not exceeded and the difference between the boiler inlet and outlet water temperatures of 20ºC is
not exceeded. In order to minimize the water missing in the installation, the water level should be
checked regularly and the leaks in the system should be removed. Because excessive water additions
to the system will cause lime accumulation on the water side of the boiler and this will cause regional
overheating and this will damage the boiler.
The boiler must not be burned directly, it must be installed on a level surface. It is recommended that
the height of the base on which the boiler is to be installed shall be at least 10 cm and its width is
wider than the outside dimensions of the boiler. Thanks to the base, the boiler is protected from the
water that can accumulate on the ground and the fan will be prevented from absorbing dust from
the ground.
Fuel must be added before emptying the hopper.
The hopper screen should not be removed while the fuel is being loaded.