background image

INSUHF0518

2

Before installing and using this product, you must read and 

understand these instructions and keep them for future reference. 

If the installer and the user do not follow these instructions, the 

manufacturer cannot be held liable in any way and the warranty 

will be null and void.
The following instructions must be adhered to in order to avoid 

personal injuries or property damages, serious injuries and poten-

tially fatal electric shocks.
If the installer or the user modifies the unit, they will be held 

responsible for any damage resulting from this modification, and 

the CSA certification could be void.

INTENDED USE

For indoor installation only.
Make sure the unit is appropriate for the intended use (if needed, 

refer to the product catalog or a representative).
RECOMMENDED HEATING CAPACITY: 1,25 W per ft

3

 (0.03 m

3

). 

This corresponds to 10 W per ft

2

 (0.09 m²) based on a standard 

ceiling height of 8 ft (2.44 m). The recommended capacity is usu-

ally sufficient for normal heating needs. Please note that the insu-

lation quality of walls and windows are some of the factors that 

influence heat losses, which modify the required capacity to heat 

a room. If needed, speak with a specialist (industrial and com-

mercial buildings) who will be able to calculate these heat losses 

and optimize the required capacity or consult the “Ressources/ 

Heating Calculator” section of the UNIWATT website.
If the unit capacity is insufficient for the size of the room, it will be 

in operation continuously, and may become defective earlier and 

turn yellow.

POSITION

Do not install the unit where objects or pieces of furniture could 

be heat damaged. Respect the following distances and positions: 

This unit must be installed at least 6 in (15 cm) from any adja-

cent surfaces and at least 6 in (15 cm) from the floor. Make sure 

objects or pieces of furniture such as, but not limited to, blankets, 

towels, beds, laundry baskets, clothing, papers, etc. do not come 

into contact with the unit, and keep them at least 36 in. (90 cm) 

from the unit. Some materials are more heat-sensitive than  others, 

so make sure those near the unit can withstand heat. Do not 

install on a wall behind a door.
This unit has hot and arcing or sparking parts inside. It is not 

designed to be used or stored in wet areas or areas containing 

flammable liquids, combustible materials or corrosive, abrasive, 

chemical, explosive and flammable substances such as, but 

not limited to, paint, gasoline, chlorine, sawdust and cleaning 

products.

RISK OF FIRE, ELECTRIC SHOCK,  

BODILY INJURY AND DAMAGE

This product must be installed by a qualified person and con-

nected by a certified electrician, according to the electrical and 

building codes effective in your region.
Protect the heating unit with the appropriate circuit breaker or 

fuse, in accordance with the nameplate.
Make sure the line voltage (volts) is consistent with that indicated 

on the unit’s nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker or fuse before 

 installing, repairing and cleaning the unit.
This unit must not come into contact with a water source and 

must be protected from splashes (e.g., splashes from a sink or 

shower). Do not use it if any part has been immersed. Moreover, 

do not turn it on or off when standing in water or if your hands 

are wet.
When starting up the unit for the first time or after a long period, 

it is normal that it produces some temporary odours.
Because this unit is hot when in use, it may pose risks even in 

normal operation. Therefore, be careful and responsible when 

using it. To avoid burns, do not let bare skin touch hot surfaces. 

The unit must cool down for few minutes since it will stay warm 

for some time after shut down.
Do not insert or allow foreign objects to enter any air vent as this 

may cause electric shocks, fires or damages to the unit.

MAINTENANCE

Some areas are dustier than others. Thus, it is the user’s res-

ponsibility to evaluate if the unit must be cleaned based on the 

amount of dirt accumulated on and inside air vents. Accumulated 

dirt can lead to a component malfunction or give a yellowish 

colour to the unit. Failure to install and maintain the unit in accor-

dance with these instructions poses a fire hasard.
Thermal protection activation indicates that the unit has been 

subjected to abnormal operating conditions. If the thermal protec-

tion remains activated it is recommended that a qualified electri-

cian or a certified repair centre examine the unit in order to make 

sure it is not damaged. (Refer to the limited warranty.)
If the unit is damaged or defective, discontinue use, cut off power 

supply at circuit breaker or fuse and have it repaired at a certified 

repair centre. (Refer to the limited warranty.)

IMPORTANT INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Содержание UHF1002TTW

Страница 1: ...ER S MANUAL WALL FAN HEATER THIS UNIT COMPLIES WITH CSA STANDARDS THANK YOU FOR YOUR PURCHASE QUESTION PROBLEM CONTACT STELPRO CUSTOMER SERVICE WWW UNIWATT CA CONTACT STELPRO COM 450 441 6020 1 866 766 6020 TM UNIWATT is a line of products manufactured by STELPRO For more information please contact customer service ...

Страница 2: ...eas containing flammable liquids combustible materials or corrosive abrasive chemical explosive and flammable substances such as but not limited to paint gasoline chlorine sawdust and cleaning products RISK OF FIRE ELECTRIC SHOCK BODILY INJURY AND DAMAGE This product must be installed by a qualified person and con nected by a certified electrician according to the electrical and building codes eff...

Страница 3: ...h a 1 4 6 5 mm diameter head minimum suitable for securing the back box directly to a stud Tool to cut drywall or gypsum board Level Phillips screwdriver Wire stripper Wire clamp Tape measure Stud finder Flat screwdriver CONTROL AND COMPATIBILITY You can control your UHF fan heater in multiple ways UHF1002WCW UHF1002TTW With a compatible wall thermostat that Has a fan heater mode Can handle the fa...

Страница 4: ...ine sawdust and cleaning products Make sure that objects or furniture near the heater can withstand the heat it gives off Do not install the heater on a wall behind a door If a piece of furniture is nearby make sure the fan heater will not impede the opening of its drawers or doors To recess your fan heater in a wall consider the following Check the construction of your wall There should be at lea...

Страница 5: ...able inside the junc tion box to connect the unit s wires easily VERTICAL INSTALLATION HORIZONTAL INSTALLATION To protect yourself from the risk of electric shock turn off the power to the lead wires from the electrical panel 3 PREPARING THE SURFACE FOR INSTALLATION WARNING This product must be installed by a certified electrician according to the electrical and building codes effective in your re...

Страница 6: ... 1 Pivot the fan heater s front panel toward the top of the unit 1 and slide it up Remove the front panel completely 2 and place it on a clean surface where it won t be damaged 2 Remove the two screws Keep the screws with the front panel 3 Lift the top 3 of the mecha nical housing A and slide it 4 to remove it from the back box B 4 Perforate one of the six pre cut holes Choose the hole according t...

Страница 7: ...in the wall making sure it is level 5 ATTACHING THE BACK BOX TO THE WALL 2 According to your installation screw the box to the wall stud using two mounting holes A NOTE If the wall finishing is not ins talled yet make sure you position the box at the correct depth so that it rests on the surface once work is complete For 1 2 inch thick finishing you can fold the side tabs and install directly on t...

Страница 8: ...o position C if required 4 Store all the wires in the back box 6 CONNECTING THE WIRING 7 ATTACHING THE MECHANICAL HOUSING TO THE BACK BOX 1 Put the mechanical housing A in the back box by inserting it into the bottom notches B provided for this purpose 2 Pivot the mechanical housing toward the wall Be careful not to trap the wires or caps 3 Secure with the screws set aside in step 4 2 UHF1002TTW m...

Страница 9: ...HF1002TTW install the timer D and mechanical thermostat E control knobs 9 TURNING THE POWER BACK ON 8 ATTACHING THE FRONT PANEL 1 Press the top of the front panel against the wall keeping it slightly tilted A and centered with respect to the mechanical housing 2 Carefully slide the front panel down until the hooks behind the front panel B are engaged and then pivot it toward the wall WARNING You m...

Страница 10: ...certified electrician in accordance with the electrical and building codes in your area Do not operate without front panel WARNING Cut off the power at the breaker or fuse before cleaning the unit High voltage and the risk of electric shock are present in the unit even if the thermostat is set to off Therefore you can receive an electrical shock as long as the unit is under power Over time cigaret...

Страница 11: ...sure it isn t defective If none of the solutions above work one or more of the heating elements may be defective Contact STELPRO Customer Service The fan heater is operating continuously Check whether the timer is at zero Make sure the unit is powerful enough for the size of the room If the fan heater never stops the thermostat or timer may be defective Contact STELPRO Customer Service The ambient...

Страница 12: ... services fur nished by it or any undertakings acts or omissions relating thereto Without limiting the generality of the foregoing STELPRO expressly disclaims any liability for property or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowdowns or for other...