IMPORTANT:
Before making electrical connections, check the specifications on the data plate,
(located on the rear access panel), to assure they agree with those of your electrical service.
WARNING:
Whenever maintenance is being performed or whenever the top cover or rear access panel
have been removed, DISCONNECT the electrical power cord and place a tag on it indicating the mixer is
being worked on.
Page 9.4
NOTES:
ATTACH AMP 925552-2
1.
ATTACH MOLEX 19002-0025(1/4" F)
2.
ATTACH MOLEX 19001-0009(3/16" M)
3.
ATTACH MOLEX 19002-0029(3/16" F)
4.
MATERIAL: 1015TEW CSA AND
5.
UL APPROVED
TO BE PACKAGED IN SEALED
6.
PLASTIC BAG WITH PART
NUMBER LABEL
PART
NUMBER
WIRE
NUMBER GA
SEE
NOTE
LENGTH
END A
SEE NOTE
END B
SEE NOTE
COLOR
8800234
W1
16
5
13
1
3
WHITE
W2
16
5
13
2
4
BLACK
W3
16
5
6
2
2
WHITE
W4
16
5
6
2
2
RED
W5
16
5
19
1
2
RED
W6
16
5
2 1/2
1
1
BLACK
W7
16
5
19
1
2
WHITE
W8
16
5
21
1
1
RED
W9
16
5
22
1
4
WHITE
W10
16
5
12
1
1
WHITE
W11
16
5
12
1
1
WHITE
W12
16
5
12
1
1
WHITE
PART OF
CONTACTOR
CW1
16
5
2 1/2
1
1
RED
CW2
16
5
7
1
1
RED
CW3
16
5
7
1
1
RED
CW4
16
5
10
1
1
BLACK
STOP
SWITCH
START
SWITCH
LEFT GUARD
SWITCH
MOTOR
RIGHT GUARD
SWITCH
BOWL LIFT
SWITCH
CW1
CW2
POWER IN
L3
L2
L1
GND
WIRING DIAGRAM
SRM 12/20
380-400V, 50HZ, 3PH
(EUROPE ONLY)
W9
W7
W8
W1
W2
W5
COLORED/PATTERNED WIRES ARE
NOT FOR REFERENCE
BUT FOR EASE OF USE
OF THIS DIAGRAM
W11
W12
W10
W3
W4
WIRING PACKAGE # 8800234
ELECTRICAL WIRING DIAGRAM
380-400V, 50HZ, 3PH (FOR EUROPE ONLY)
FIGURE 2C