![background image](http://html.mh-extra.com/html/universal-weight-electronics/vgw-series/vgw-series_operation-manual_1059339016.webp)
2. If scale detects the unit piece weight of the sample is smaller than minimum
unit weight, the PCS sign will start flashing as warning (unit piece weight
must not small than 0.5d). It is recommended using smaller capacity scale
for this sampling.
3. When PCS sign flashes, sampling process can still in process but might result
errors.
5.5 CHECK WEIGHING FUNCTION
The scale is equipped with check weighing function which allowing users to set
high and low limits to quickly checking the weight of each product within the
range or not.
a. Indicator is on and both Zero indicator and Stable indicator are on
b. Press and hold
MODE
until display shows
CHK W
c. Press
MODE
to enter and display shows Hi for hi limit setting, press
ZERO
for value increment and
TARE
for shifting digits. Press
MODE
to confirm and
entering low limit setting
d. Display shows
LoW
, press
ZERO
for value increment and
TARE
for shifting
digits. Press
MODE
again to confirm and entering alarm setting
e. Display shows
bEEP
first and then showing
bb-no
, press
ZERO
for options
bb-Go
,
bb-H.L
,
bb-Hi
, and
bb-Lo
Display
Description
bb-no
No alarm for any weighing result
bb-Go
Alarm activates when weighing result falls within the range
bb-H.L
Alarm activates when weighing result falls outside the range
bb-Hi
Alarm activates when weighing result higher than the range
bb-Lo
Alarm activates when weighing result lower than the range
NOTE:
1. Check weighing function can be engaged under any weighing unit including
piece counting mode. When the weighing unit is PCS and check weighing
mode is activated, display will show
CHK P
for checking piece.
2. If check weighing limits have been programmed before, display will show
PrEV
for resuming the previous setting or not when entering the setup.
Press
MODE
to confirm using the previous setting or
ZERO
to set new limits.
3. To temporary disable check weighing function, press and hold
MODE
again
to enter check weighing setup and press
ZERO
when displays
CHK W