INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY.
CAUTION: THIS SMOKE ALARM IS SEALED. THE COVER IS NOT REMOVABLE

!

• A mounting bracket is provided on the back of the alarm.
• Remove the mounting bracket from the back of the alarm by holding the mounting bracket and

twisting the alarm in the direction indicated by the "TWIST TO REMOVE" arrow on the side of the
alarm base.

OPTIONAL TAMPER RESISTANT FEATURES:

 There are two separate tamper resistant locking

features provided for this model. Activating one or both of these features deters someone from
removing the smoke alarm from the mounting bracket or removing the battery from the alarm. The
breakaway locking pins are clearly marked and molded into the mounting bracket. Refer to the
diagram on the next page.

TO ACTIVATE THE LOCKING FEATURES:

 Do not activate the locking features until you have

activated the battery, mounted the smoke alarm to the bracket and tested the smoke alarm. Refer to
OPERATION, TESTING & MAINTENANCE instructions on Page 6.
1.

Detach the breakaway alarm locking pin from the mounting bracket.

AVOID THESE LOCATIONS

• the garage – products of combustion are produced when you start your vehicle.
• near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces,

gas hot water heaters). Use smoke alarms with photoelectric sensors or smoke alarms with
Silence Feature  for these areas.

• in areas with high humidity, like bathrooms or areas near dishwashers or washing machines.

Install at least 3 feet (0.9 meters) away from these areas.

• in areas of turbulent air such as air returns or heating and cooling supply vents, smoke alarms

shall not be located where airflow prevents smoke from reaching the alarms.

• in extremely dusty, dirty or insect-infested areas. Loose particles interfere with smoke alarm operation.
• in areas where temperature may fall below 40

0

F (4.4

0

C) or rise above 100

0

F (37.8

0

C).

• closer than 1 foot (0.3m) from fluorescent lights, electrical "noise" and flickering may affect the

alarm's operation.

• closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling suspended (paddle) fan.
• on a poorly insulated ceiling or exterior wall (mount smoke alarm on an inside wall).

Page 4

Early warning fire detection is best achieved by the installation of fire detection equipment in
all rooms and areas of the household as follows: A smoke alarm installed in each separate
sleeping area (in the vicinity of, but outside of, the bedrooms); and, as appropriate, heat or
smoke alarms in living rooms, dining rooms, kitchens, hallways, attics, furnace rooms, closets,
utility storage rooms, basements and attached garages. Test the alarms weekly to assure
proper operation.

2.

Insert the pin into the hole for the feature you are activating. Refer to the diagram below for
correct placement.

THIS SMOKE ALARM WILL NOT WORK WITHOUT A GOOD BATTERY
PROPERLY INSTALLED. THE SMOKE ALARM SHOULD BE TESTED WHEN
INSTALLED AND THEN TESTED WEEKLY AFTER THAT.

ALARM/BRACKET

LOCKING PIN

BATTERY LOCKING PIN

INSERT ALARM

LOCKING PIN HERE

INSERT BATTERY

LOCKING PIN HERE

Содержание MP308

Страница 1: ...uctions 4 Locking Tamper Feature 4 Operation Testing Maintenance 5 RV Installation 5 Quick Find Alarm Originating Feature Reset 5 Cautions Warnings 6 Battery Replacement 6 Develop and Practice a Plan...

Страница 2: ...ERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR L...

Страница 3: ...4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be l...

Страница 4: ...areas near dishwashers or washing machines Install at least 3 feet 0 9 meters away from these areas in areas of turbulent air such as air returns or heating and cooling supply vents smoke alarms shall...

Страница 5: ...ire is present check to see if one of the reasons listed above may have caused the alarm Use the Silence Feature if it is a nuisance alarm or reset the alarm by pressing and holding the test button fo...

Страница 6: ...e Energizer LA522 Ultralife U9VL J or Ultralife U9VL J P from your local retailer Lithium Battery Models only The Lithium battery is warranted to last for 10 years under normal operating conditions Re...

Страница 7: ...ultiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of each separate dwelling unit sleeping area within 6 4 m 21 ft of any door to a sleeping r...

Страница 8: ...or approx 10 seconds or temporarily remove and then replace the battery This will clear alarm origination Reset alarm after every alarm event Silent 1 Chirp approx every 40 seconds Condition Low Batte...

Страница 9: ...T AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE L...

Отзывы: