RECOMMENDED LOCATION OF ALARMS

• Locate the first smoke alarm in the immediate area of the bedrooms. Try to protect the escape

route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists,
locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters)
long, install a smoke alarm at each end.

• Locate additional smoke alarms to protect any stairway as stairways act like chimneys for

smoke and heat.

• Locate at least one smoke alarm on every floor level.
• Locate a smoke alarm in any area where a smoker sleeps or where electrical appliances are

operated in sleeping areas.

• Smoke, heat and other combustion products rise to the ceiling and spread horizontally. Mounting

the smoke alarm on the ceiling in the center of the room places it closest to all points in the room.
Ceiling mounting is preferred in ordinary residential construction. However, in mobile homes, wall
mounting on an inside partition is preferred to avoid the thermal barrier that may form at the ceiling.

• When mounting smoke alarm on the ceiling, locate it a minimum of 4" (10cm) from a side wall or

corner (see Diagram A).

• When mounting smoke alarm on a wall, if local codes allow, use an inside wall with the top edge

of the smoke alarm a minimum of 4" (10cm) and a maximum of 12" (30.5cm) below the ceiling/
wall intersections (See Diagram A).

Page 3

Sloped Ceilings (Peaked Ceilings):
Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (914 mm)
horizontally of the peak, but not closer than 4 in. (102 mm) vertically to the peak.

Sloped Ceilings (Shed Ceilings):
Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft. in 8 ft. (1 m
in 8 m) horizontally shall be located within 36 in. (914 mm) of the high side of the ceiling, but not closer
than 4 in. (102 mm) from the adjoining wall surface.

Tray-Shaped Ceilings:
Smoke Alarms or smoke detectors shall be installed on the highest portion of the ceiling or on the sloped
portion of the ceiling within 12 in. (305 mm) vertically down from the highest point.

Mobile Home Installation:
For minimum protection, smoke alarms  should be installed in compliance with H.U.D. Manufactured Home
Construction Safety Standards, Title 24 CFR, Section 3280.208 and Section 3282. For additional protection,
see Single Story Residence smoke alarm requirements/recommendations for Existing Homes and New
Construction Homes.

Note: For mobile homes built before 1978, install smoke alarms on inside walls between 4” and 12” from
the ceiling (older mobile homes have little or no insulation in the ceiling). This is especially important if the
ceiling is unusually hot or cold.

Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area.

Existing Homes:
The NFPA requires a smoke alarm on every level and outside each sleeping area in existing construction.
An existing household with one level and one sleeping area is required to have one smoke alarm.

New Construction Homes and Manufactured Homes:
The NFPA requires AC-powered, interconnected smoke alarms to be installed inside each bedroom, outside
each bedroom area, and on every level of the home. They also require a minimum of two AC-powered,
interconnected smoke alarms in any new construction home.

Содержание MP308

Страница 1: ...uctions 4 Locking Tamper Feature 4 Operation Testing Maintenance 5 RV Installation 5 Quick Find Alarm Originating Feature Reset 5 Cautions Warnings 6 Battery Replacement 6 Develop and Practice a Plan...

Страница 2: ...ERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR L...

Страница 3: ...4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be l...

Страница 4: ...areas near dishwashers or washing machines Install at least 3 feet 0 9 meters away from these areas in areas of turbulent air such as air returns or heating and cooling supply vents smoke alarms shall...

Страница 5: ...ire is present check to see if one of the reasons listed above may have caused the alarm Use the Silence Feature if it is a nuisance alarm or reset the alarm by pressing and holding the test button fo...

Страница 6: ...e Energizer LA522 Ultralife U9VL J or Ultralife U9VL J P from your local retailer Lithium Battery Models only The Lithium battery is warranted to last for 10 years under normal operating conditions Re...

Страница 7: ...ultiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of each separate dwelling unit sleeping area within 6 4 m 21 ft of any door to a sleeping r...

Страница 8: ...or approx 10 seconds or temporarily remove and then replace the battery This will clear alarm origination Reset alarm after every alarm event Silent 1 Chirp approx every 40 seconds Condition Low Batte...

Страница 9: ...T AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE L...

Отзывы: