Goodrive10 inverters Function codes
57
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P08.44
UP/DOWN
terminals
control setting
0x00~0x221
LED ones: frequency control selection
0:UP/DOWN terminals setting valid
1:UP/DOWN terminals setting invalid
LED tens: frequency control selection
0:Only valid when P00.06=0 or P00.07=0
1:All frequency means are valid
2:When the multi-stage are priority, it is invalid to the
multi-stage
LED hundreds: action selection when stop
0:Setting valid
1:Valid in the running, clear after stop
2:Valid in the running, clear after receiving the stop
commands
0x000
○
P08.45
UP terminal
frequency
increasing
integral ratio
0.01~50.00 Hz/s
0.50 Hz/s
○
P08.46
DOWN
terminal
frequency
integral ratio
0.01~50.00 Hz/s
0.50 Hz/s
○
P08.47
Action when
the frequency
setting is off
0x000~0x111
LED ones: The action selection when the digital adjusting
the frequency is off.
0:Save when the power is off
1:Clear when the power is off
LED tens:The action selection when MODBUS set
frequency is off
0:Save when the power is off
1:Clear when the power is off
LED tens:The action selection when the other frequency
set frequency is off
0:Save when the power is off
1:Clear when the power is off
0x000
○
P08.50
Magnetic flux
braking
This function code is used to enable magnetic flux.
0: Invalid.
100~150: the bigger the coefficient, the bigger the braking
strength.
This inverter can slow down the motor by increasing the
0
●