(1)
If the error is generated by the integrated manifold, it is possible to reset the error by turning off all the 24 outputs, wait for at least 7
seconds, and reactivate the needed outputs again.
In case of short circuit or overload all the 24 outputs will be switched off.
(2)
Only on output modules.
(3) The type of emergency frame is 0x81 (Manufacturer Error + Generic Error)
, they are separated for inputs and outputs
and are also generated when the cause of the error is removed.
Nota 1:
The system generates an Emergency message in case one or more input modules are in error
.
Nota 2:
The system generates an Emergency message in case one or more output modules are in error.
Nota 3: The system generates two Emergency messages in case one or more input and output modules are in
error.