background image

Vision™ OPLC™V560, V560-T25B 

Installation Guide

8

Unitronics 

CANbus

These controllers comprise a CANbus port. Use 
this to create a decentralized control network using 
one of the following CAN protocols: 

CANopen: 127 controllers or external 
devices 
CANLayer 2 
Unitronics’ proprietary UniCAN: 60 
controllers, (512 data bytes per scan) 

The CANbus port is galvanically isolated. 

CANbus Wiring 

Use twisted-pair cable. DeviceNet® thick shielded 
twisted pair cable is recommended. 

Network terminators: These are supplied with the 
controller. Place terminators at each end of the 
CANbus network.  

Resistance must be set to 1%, 121

R

, 1/4W. 

Connect ground signal to the earth at only one 
point, near the power supply. 

The network power supply need not be at the end 
of the network 

CANbus Connector 

The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole 

discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or 
temporarily withdraw any of the forgoing from the market. 
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of 

merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in 

this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising 
out of or in connection with the use or performance of this information. 
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other 

third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them.

 

DIG-V560-T25B 08/10

 

Содержание Vision OPLC V560-T25B

Страница 1: ...ation I O Expansion Modules Local or remote I Os may be added via expansion port or CANbus Installation instructions and other data may be found in the module s technical specification sheet Information Mode This mode enables you to Calibrate the touchscreen View Edit operand values COM port settings RTC and screen contrast brightness settings Stop initialize and reset the PLC To enter Information...

Страница 2: ...on Use caution Before using this product the user must read and understand this document All examples and diagrams are intended to aid understanding and do not guarantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should...

Страница 3: ...cover on the rear of the controller 1 Remove the battery cover shown on page 4 The polarity is marked on the battery holder and on the battery 2 Insert the battery ensuring that the polarity symbol on the battery is facing up aligned with the symbol on the holder 3 Replace the battery cover Mounting Dimensions Note that the LCD screen may have a single pixel that is permanently either black or whi...

Страница 4: ... the right 2 Slide the controller into the cut out ensuring that the rubber seal is in place 3 Push the 4 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cu...

Страница 5: ...etely into the terminal to ensure a proper connection 4 Tighten enough to keep the wire from pulling free Power Supply The controller requires either an external 12 or 24VDC power supply Permissible input voltage range 10 2 28 8VDC with less than 10 ripple The power supply must include double insulation Outputs must be rated as SELV PELV Class 2 Limited Power Do not connect either the Neutral or L...

Страница 6: ...control signals are not used which is the standard case RS232 RS485 Controller Port Pin Description Pin Description Pin 1 1 DTR signal 1 A signal 2 0V reference 2 RS232 signal 3 TXD signal 3 RS232 signal 4 RXD signal 4 RS232 signal 5 0V reference 5 RS232 signal 6 DSR signal 6 B signal Standard programming cables do not provide connection points for pins 1 and 6 When a port is adapted to RS485 Pin ...

Страница 7: ...pen the locking mechanism 3 Gently rock the module from side to side easing the module from the controller Re installing a Snap in I O Module 1 Line the circular guidelines on the controller up with the guidelines on the Snap in I O Module as shown below 2 Apply even pressure on all 4 corners until you hear a distinct click The module is now installed Check that all sides and corners are correctly...

Страница 8: ...at any time at its sole discretion and without notice to discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of ...