background image

27

Ÿ

Power supply :                                                  

           220~240VAC, 50HZ.  

TECHNICAL SPECIFICATIONS

UNITO INFINITY Smart Water System

Ÿ

Dispensing water types :        

                         Sparkling water, Ambient 

water, Boiling water, Chilled water, Cold/Hot tap water.

Ÿ

Boiling time:          

                                 15 minutes (from  25

°

C to 100

°

C).

Ÿ

BTank capacity:     

                    850 cc Sparkling. Boiling water: 4.4 Liter, 

water, 2 Liters cold water.

Ÿ

Cooling time:          

                                   30 minutes (from  25

°

C to

 3°

C).

Ÿ

System max. safety pressure:        

                                   8 bar (800 kPa).

Ÿ

Min./Max. mains pressure:            

                           2/5 bar (200/500 kPa).

Ÿ

Max. hot water temperature: 

                                                           100°C.

Ÿ

Safety features:            

Maximum temperature fuse, Safety valve(including 

pressure relief valve , a built-in one direction valve & on/off valve).

Ÿ

Dimensions:    

                                                             485 x 250 x 484 mm.                                                                                          

Ÿ

Weight:     

                                                                                           27 KG. 

Ÿ

Standby power consumption :                                                        

  2.5 W.

Ÿ

Flow rate:                                               

                                2 L/min @3bar.

Ÿ

Operation:          

                   Operation via Electronic control knob, handle.  

Ÿ

Max. power consumption:                                                              

1650 W.

Ÿ

Max. water hardness

 

:                  

                                                    10

°

 dH.

Regular maintenance of the UNITO INFINITY Smart Water 
System is required to prevent damage or downtime. Service 
should be performed by qualified and certified personnel only.

Warning:

 

Disconnect the power supply from the UNITO INFINITY 

Smart Water System before maintaining the unit

CARE AND MAINTENANCE

Ÿ

Clean exterior surfaces of the unit with a soft, lint-free cloth. 
Never use alcohol, paint thinner, benzene or other solvents to 
clean this unit. Never use an abrasive material such as a 
brush or scouring pad to clean surfaces.

Ÿ

Close/open the system valve and safety valve every 6 
months.

Ÿ

Always test your cleaning solution on an inconspicuous area 
before applying to the entire surface.

Ÿ

Keep the UNITO INFINITY Smart Water System in a dry, 
clean space. Minimize exposure to dust. Power button or 
other controls should never be wet.

Ÿ

Wipe surfaces clean after applying cleaner.

Ÿ

Never expose the unit to vibration.

Ÿ

In the event of mechanical/power failure or damage, do not 
attempt to repair the system unit or wires. Call a certified 
technician.

Ÿ

If the UNITO INFINITY Smart Water System requires service, 
please consult a certified dealer. Unauthorized service may 
void the warranty.

Ÿ

Clean aerator once a year.

Ÿ

If the unit becomes wet, immediately shut it down. Wait for the 
unit to completely dry before turning it on again.

Ÿ

Make sure that all cabin ventilation outlets are always free 
and clear.

TROUBLESHOOTING

Read and follow the assembly instructions. If the UNITO 
INFINITY Smart Water System is not functioning, please check 
troubleshooting table. If the water system is still not working 
properly, disconnect power supply and contact authorized 
UNITO customer service center for assistance. When calling for 
assistance, please provide your product model and serial 
number.

Symptom

Possible Cause   

Solution   

No water 

owing, the 

water is 

owing too 

slow

- Main water supply valve 
is turned off.

- Turn on the main water 
supply valve.

- The water system is not 
connected properly.

- Connect all the cable 
and hose correctly.

- Hoses are bended.

- straighten the hoses. 

- There is limescale or dirt 
in the aerator.

- Clean/replace the 
aerator.

- Filter wrong installation

- check the filter 
connection.

The water is 

sputtering or 

is irregular

- There is no or too little 
water pressure.

- Check the water 
pressure. It should be 
above 1.0 bar. Check a 
different tap. If the 
pressure is also low 
there, check the mains 
water tap and contact 
your water supplier.

Air/water 

dripping from 

the faucet 

while 

preparing 

soda  

- High pressure in CO2 
cylinder.

Normal behavior due to 
high pressure, normally 
when using a new 
cylinder.

No boiling 

water

- The boiler is turned off or 
not connected to power 
supply wall socket.

- Connect to power 
supply.

- Safety valve or main 
water supply valve is 
turned off.

- Turn on the Safety valve 
or main water supply 
valve.

- Faulty Safety valve(cut-
off).

- Contact UNITO 
customer service.

- the boiler is not activated

- Follow page 14 step A 
to C

No Chilled 

water

- The Chiller is powered 
off or not connected to 
power supply wall socket.

- Connect to power 
supply.

- Faulty function of chiller.

- Restart the system.

- Faulty 
cables/hoses/control knob.

- Contact UNITO 
customer service.

No Soda or 

Soda is weak

The CO2 cylinder not 
installed or not installed 
properly.

- Install the CO2 cylinder 
properly.

- CO2 cylinder is empty.

- Replace with a new 
CO2 cylinder.

- Soda intensity setting is 
low.

- Change to a higher 
intensity level soda 
through the UNITO 
mobile APP.

Содержание INFINITY BWXX01

Страница 1: ...UNITO INFINIFY Smart Water System 22 25 NL 26 29 GB 30 33 DE 34 37 FR 1 1 2 2 22 37 3 14 17 17 18 21 15 16 REV BWXX01...

Страница 2: ...1 50 0 262 0 422 1 28 0 188 5 149 5 43 0 485 0 484 0 250 0 220 8 102 0 8 5...

Страница 3: ...2...

Страница 4: ...3 35 36 1 50...

Страница 5: ...4 2 3 Festdrehen der Wasserschl uche Resserrer les tuyaux Vastdraaien van de slangen Tighten the hoses Option 2 4 Option 1...

Страница 6: ...5 5 Option 2 Option 2 Option 2 Page 6 A or C Page 6 B d 35mm MARKING PAPER...

Страница 7: ...6 6 Option 1 Option 2 Option 3 C...

Страница 8: ...7 8 7 A1 B1 Option 1 Option 2...

Страница 9: ...8 9 C1 10 Option 3...

Страница 10: ...9 11 12 13 8...

Страница 11: ...10 14 15...

Страница 12: ...11 16 17...

Страница 13: ...12 18 00 00 FILTER CO2 00 00 FILTER CO2 UNITO ANYWHERE APP SETTINGS APP USER MANUAL...

Страница 14: ...servoir de la chaudi re Temperaturanzeige des K hlertanks A chage de la temp rature du r servoir du refroidisseur 5 Weergave temperatuur koeltank Chiller tank temperature display Bouton marche arr t...

Страница 15: ...14 20 30 Sec 30 Sec 3 X Kort indrukken 3 X Quick press 3 X Presse rapide 3 X Schnelles Dr cken 30 Minutes 15 Minutes...

Страница 16: ...1 100 C 2 Ambient water Long press Langes Dr cken Presser longuement Land indrukken 2 X quick press 2 X Presse rapide 2 X Kort indrukken 2 X Schnelles Dr cken 1 X Kort indrukken 1 X quick press 1 X Sc...

Страница 17: ...euwe soda vindt automatisch plaats zodra de tank volledig leeg is Une fois le r servoir rempli le syst me reproduira automatiquement de l eau gazeuse The system will automatically remake soda once the...

Страница 18: ...EVERY 6 MONTHS DISINFECTION KIT IS AVAILABLE FOR PURCHASE AT WWW UNITOSTORE COM BEACHTUNG ALLE 6 MONATE WIRD EIN DESINFEKTIONSVERFAHREN EMPFOHLEN DESINFEKTIONS KIT IST F R DEN KAUF BEI ERH LTLICH WWW...

Страница 19: ...18 OPTIONAL ITEM...

Страница 20: ...19 2 Mixer...

Страница 21: ...20 4 G1 2...

Страница 22: ...21...

Страница 23: ...idvanhetproductteverlengen Filterskunnen onlinewordenbesteldopdewebsitehttp www unitostore com De wateropslagverwarmer is alleen geschikt voor gebruik binnenshuis NL Koppel de eenheid los wanneer deze...

Страница 24: ...schone plek Minimaliseer blootstelling aan stof Aan uit knop of andere bedieningselementen mogen nooit nat zijn Als het apparaat nat wordt moet u het onmiddellijk uitschakelen Wacht tot het apparaat...

Страница 25: ...aanvraagt moet u het volgende verstrekken 1 Het aankoopbewijs of ander bewijs van de datum en plaats van aankoop 2 Een beschrijving van het probleem met het apparaat 3 Levering van het product of het...

Страница 26: ...ontact op met uw lokale overheid of met de winkel waar u het product hebt gekocht Het UNITO INFINITY Smart Water System moet worden verwijderd in overeenstemming met de lokale wet en regelgeving die o...

Страница 27: ...ter water for to maintain satisfactory hygiene and to extend the products life Filters can be ordered online at the webshop http www unitostore com The boiling water storage heater and plug must not b...

Страница 28: ...ce a year If the unit becomes wet immediately shut it down Wait for the unit to completely dry before turning it on again Make sure that all cabin ventilation outlets are always free and clear TROUBLE...

Страница 29: ...em must be disposed in accordance with local laws and regulations applicable to that location Once the product reaches end of its life and needs to be disposed local authorities should be contacted fo...

Страница 30: ...and all rights are reserved This publication may not be copied for commercial purposes in any form in whole or in part without the prior written consent of UNITO The UNITO logo is a trademark of UNITO...

Страница 31: ...sonen die mit dem Smart Water System UNITO INFINITY nicht vertraut sind ber die sichere Handhabung des Systems Unsachgem e Verwendung kann zu Sch den oder Verletzungen f hren DE Wenden Sie sich an ein...

Страница 32: ...Siedekapazit t 850 cc Sprudelwasser Siedewasser 4 4 Liter 2 Liter Kaltwasser System max Sicherheitsdruck 8 bar 800 kPa Spannungsversorgung 220 240VAC 50HZ Standby Leistungsaufnahme 2 5 W Min Max Haupt...

Страница 33: ...Kaltwasser Der K hler ist ausgeschaltet oder nicht an die Steckdose angeschlossen An die Stromversorgung anschlie en Fehlerhafte Funktion der K ltemaschine Starten Sie das System neu Fehlerhafte Kabel...

Страница 34: ...ne Marke von UNITO SMART TECHNOLOGIES LTD Die Verwendung des UNITO Logos f r kommerzielle Zwecke ohne vorherige schriftliche Zustimmung des Unternehmens kann eine Markenverletzung darstellen HAFTUNGSA...

Страница 35: ...emp rature de fonctionnement 5 C 50 C 41 F 122 F Les travaux d installation lectrique ne doivent tre e ectu s que par un lectricien quali et conform ment toutes les r glementations nationales et local...

Страница 36: ...de refroidissement 30 minutes de 25 C 3 C ambiant 25 C Puissance absorb e max 1650 W Poids de l appareil 27 KG Duret max de l eau 10 dH ENTRETIEN ET MAINTENANCE L entretien r gulier du syst me d eau...

Страница 37: ...chaudi re est teinte ou n est pas branch e la prise murale d alimentation lectrique Raccorder l alimentation lectrique La soupape de s curit ou la soupape principale d alimentation en eau est ferm e O...

Страница 38: ...n conform ment aux lois et r glementations locales applicables cet endroit Une fois que le produit est en n de vie et doit tre limin vous devez contacter les autorit s locales pour conna tre les optio...

Страница 39: ...info unito tech com www unito tech com...

Отзывы: