CHAPTER 2: GENERAL SETUP
MODEL HF2 2 kHz HIGH FREQUENCY RESISTANCE WELDING POWER SUPPLY
990-057
2-3
HF2 Weld Transformer Electrical Specifications
Model Input
Volts
(Rms)
Input kva
(Rms)
Duty Cycle ( %) Peak Open Ckt
Output Voltage
Peak Output
Max. (Amps)
Max Sec
Resist. (
μΩ
)
X3/4/380A 380 9
6
6.5
4,000
500
X3/4/460A 460 9
6
6.5
4,000
500
X3/4000A 230
9
6
6.5
4,000
500
X9/6000A 230 19
6
9.3
(32:1
TR) 4,900
500
X11/4/460A
380 4
5 11.8
(44:1
TR)
10.0 (52:1 TR)
8.6 (60:1 TR)
7.5 (68:1 TR)
4,000
4,000
4,000
4,000
1,300
1,100
950
825
460 4
5 14.3
(44:1
TR)
12.1 (52:1 TR)
10.5 (60:1 TR)
9.2 (68:1 TR)
4,000
4,000
4,000
4,000
1,300
1,100
950
825
X11/4000A 230
15
5
10.7
10.0 (52:1 TR)
8.6 (60:1 TR)
8.7
8.8
8.9
4,000
4,000
4,000
1,300
1,100
TRANSFORMER SPECIFICATION NOTES:
1
For the Model X11/4/460A, turns ratios
(TR) are selectable by a switch on the
transformer rear panel.
2
HF2 Weld Control Input voltage selection
must be jumpered at E12 on the HF2 Weld
PCB as shown in Figure 2-3. E12 is
located at the center of the PCB left edge.
3
Maximum weld time at Maximum Short
Circuit Current is 50 milliseconds.
Figure 2-3. Voltage Jumpers