Classic Q3 1000-2000A
6
Q3 400/450-1000-2000
Power connection
360 ... 440V~
Auxiliary voltage connection
360 ... 440V~, 200 … 250V~ oder Option
Output voltage
max. ± 450V=
Cooling
ventilation fan
Field supply - external
Field current controller F2.1 400/340-20
Q3 400/450-
1000
1500
2000
Input current
A~
800
1200
1600
Output current
- peak 5s
- continuous
A=
A=
2000
1000
3000
1500
4000
2000
El. power
kW
450
675
900
Fuses
ff
AFF
installed
6x1000
installed
12x1000
installed
12x1000
Power chokes
Type
3x
KU240-1000
3x
KU240-1500
3x
KU240-2000
mH
0,05
0,03
0,02
Armature chokes
Armature chokes are necessary only for special applications
Dimensions w
x
h
x
d
mm
550x800x520
550x800x520
550x800x520
Q3 500/550-1000 bis 2000
Power connection
450 ... 550V~
Auxiliary voltage connection
360 ... 440V~, 200 … 250V~ oder Option
Output voltage
max. ± 550V=
Cooling
ventilation fan
Field supply - external
Field current controller Unitek F2.1 400/340-20
Q3 500/550
-
1000
1500
2000
Input current
A~
800
1200
1600
Output current
- peak 5s
- continuous
A=
A=
2000
1000
3000
1500
4000
2000
El. power
kW
550
825
1100
Fuses
ff
AFF
Installed
6x1000
Installed
12x1000
Installed
12x1000
Power chokes
Type
3x
KU240-1000
3x
KU240-150
0
3x
KU240-2000
mH
0,05
0,03
0,02
Armature choke
Armature chokes are necessary only for special applications
Dimensions w
x
h
x
d
mm
550x800x52
0
550x800x52
0
550x800x52
0
T
ec
hn
ic
a
l
d
a
ta
Содержание Classic Q3 Series
Страница 10: ...Classsic Q3 1000 2000A 10 Dimensions ...
Страница 11: ...3 Electrical installation Q3 1000 2000A 11 Dimensions ...
Страница 13: ...3 Electrical installation Q3 1000 2000A 13 Connections ...
Страница 18: ...Q3 1000 2000A 18 Free ...
Страница 20: ...Q3 1000 2000A 20 Field regulator is not installed External field current regulator F2 1 xx Field connection ...