5 Adjustments
Q3 1000-2000A
21
Actual value connection
Tacho
Suitable actual value encoders:
- DC tacho generator
- Brushless tacho generator with evaluation electronics
- Incremental encoders with evaluation electronics
Note: AC or three-phase tachos with rectification are not suitable
Connection
Control electronics (see Manual REG)
In case of a positive command value
Tacho positive
X 1:8b
Tacho negative
X 1:9
Shield
X 1:8
Armature voltage
Ground referenced actual value
Fuses
2x 0.1A >>> directly in the armature circuit
For armature voltage
>180V= >>> additional resistors are required
Use unit UNITEK EXZU-UA1
(two resistors and two fuses in insul. case)
Note:
Observe Manual REG
Option:
In case of internal potential-free armature voltage
control please indicate on order.
A
ct
u
a
l
v
a
lu
e
13
10
*Only by U > 180V
Содержание Classic Q3 Series
Страница 10: ...Classsic Q3 1000 2000A 10 Dimensions ...
Страница 11: ...3 Electrical installation Q3 1000 2000A 11 Dimensions ...
Страница 13: ...3 Electrical installation Q3 1000 2000A 13 Connections ...
Страница 18: ...Q3 1000 2000A 18 Free ...
Страница 20: ...Q3 1000 2000A 20 Field regulator is not installed External field current regulator F2 1 xx Field connection ...
Страница 23: ...5 Adjustments Q3 1000 2000A 23 Circuit diagram ...