3 Electrical installation
Q3 1000-2000A
19
M
o
to
r
co
nn
e
ct
io
n
Connection
positive command value
Motor-
bolt X10:13
Motor+
bolt X10:10
Note:
Armature choke only for a few applications
Inductance:
L
[
mH
]
= U
A
/I
A
x 0.8
Standard version without a choke
Motor lines have to be shielded.
Unit Q3 x/x-
Power choke*
Min. conductor
cross-section (mm²)
Type current
Direct current
1000
auf Anfrage
2x 240
1500
auf Anfrage
2x 240
2000
auf Anfrage
2x 240
* Chokes are necessary only for special applications
Switching in the armature circuit
- dc circuit current-free
- disable inactive
Warning:
Faulty switching will create arcing across the switch contacts.
Power supply failure - brake resistor
Break contact of the mains contactor K1
Rating: Resistor RNB = max. armature voltage/2 x type current
Attention:
Power lines have to be shielded and routed separately from control lines!
For electro-magnetic interferences please refer to the CE advice.