Q3 1000-2000A
14
CE Advice
The devices adhere to the EU guidelines 89/336/EWG and the technical stan-
dards EN 61000-2 and 61000-4 provided that the following conditions are ob-
served:
- The device, the transformer, and filter capacitors are mounted on a 500x500x2
mm mounting plate.
- The mounting plate must be connected to ground using a 10mm² wire.
- The motor housing must be connected to ground using a 10mm² wire.
- The device ground X1:8 must be connected to the mounting plate using a
2.5mm² wire.
- Device PE screw must be connected to the mounting plate using a 4mm² wire,
l = 50mm.
Three-phase connection:
Power choke type:
see technical details
Filter capacitors:
0.5mF/600V~
3 x 1mF (x) + 1 x 1mF (y)
Conductor length between the device and the power choke <250mm
Motor connection:
Motor conductors
l = 1.5m, shielded
Tacho and all control lines
l = 1.5m, shielded
Shielding connected to PE
Connections diagram
C
E
-A
d
v
ic
e
Содержание Classic Q3 400 Series
Страница 10: ...Classsic Q3 1000 2000A 10 Dimensions ...
Страница 11: ...3 Electrical installation Q3 1000 2000A 11 Dimensions ...
Страница 13: ...3 Electrical installation Q3 1000 2000A 13 Connections ...
Страница 18: ...Q3 1000 2000A 18 Free ...
Страница 20: ...Q3 1000 2000A 20 Field regulator is not installed External field current regulator F2 1 xx Field connection ...
Страница 23: ...5 Adjustments Q3 1000 2000A 23 Circuit diagram ...