background image

-7-

WRONG

RIGHT

FIG. 7

WRONG

FIG. 5

ELBOW

COLLAR

THIMBLE

FLOOR PROTECTOR

FLUE  CONNECTION-NON-COMBUSTIBLE  WALL

PIPE

NONCOMBUSTIBLE WALL

PIPE

BAROMETRIC

DRAFT REGULATOR

FIG. 6

PIPE  REDUCER

FLOOR PROTECTOR

3 FT. MIN.

2 FT. MIN

10 FT.

CHIMNEY CAP MANDATORY

11 FT. MINIMUM

BAROMETRIC

DRAFT REGULATOR

PIPE

NONCOMBUSTIBLE

CONSTRUCTION IN

ACCORDANCE WITH

NFPA 211

Chimney Connection

MASONRY CHIMNEY

The  masonry  chimney  must  be  code  approved  and  have  a  flue  liner. 

The masonry chimney must comply with UL, ULC codes. Before using an 

existing masonry chimney, clean the chimney and inspect the flue liner 

to be sure it is safe to use. Make repairs before attaching the heater. The 

connector pipe and fittings you will need to connect directly to a masonry 

chimney are shown. If the connector pipe must go through a combustible 

wall before entering the masonry chimney, consult a qualified mason or 

chimney  dealer.  The  installation  must  conform  to  local  fire  codes,  and 

NFPA  211(USA)  or  CAN/CSA-B365-M91  (Canada).  Do  not  connect  this 

heater into the same chimney flue as the fireplace or flue from another 

heater.  The  chimney  used  for  a  heater  must  not  be  used  to  ventilate 

the cellar or basement. If there is a cleanout opening at the base of the 

chimney, close it tightly.

UL/ULC LISTED CHIMNEY

Carefully  follow  the  chimney  manufacturer's  instructions.  Use  only  listed 

type HT per UL 103, ULC, 6-in diameter black or blued chimney connector, 

minimum 24 gauge steel. If your chimney starts at the ceiling, you will need 

enough 6" pipe to reach the ceiling. The top of the chimney must be at 

least 3 feet above the roof and be at least 2 feet higher than any point of 

the roof within 10 feet. Use double or triple wall pipe for the exterior portion 

of the chimney.

RULES FOR CONNECTOR PIPE INSTALLATION

1.  The crimped end of the pipe must be installed toward the heater. 

The  pipe  should  slide  into  the  flue  collar.  The  pipe  should  be  firmly 

attached  to  the  flue  collar  with  3  screws  and  sealed  with  furnace 

cement.

2.  Slope any horizontal pipe upward toward the chimney at least 1/4" for 

each foot of horizontal run. The horizontal section must be a minimum 

of 24" from the stove.

3.  You must have at least 18" inches clearance between any horizontal 

piping and the ceiling.

4.  The pipe cannot extend into the chimney flue.

5.  Seal each connector pipe joint with furnace cement. Also, seal the 

pipe at the chimney. Seal the inside with high-temperature silicone 

and the outside with high-temperature tape.

6.  Use 3 sheet metal screws at each joint to make the piping rigid.

7.  It is recommended that no more than two (2) 90-degree bends be 

used in the stove pipe installation as more than two (2) may decrease 

the amount of draw and possibly cause smoke spillage.

NOTE: The chimney connector shall not pass through an attic, roof space, 

floor, ceiling, or similar concealed space. Where passage through a wall 

or  partition  of  combustible  construction  is  desired,  the  installation  must 

conform with CAN/CSA - B365.

IMPORTANCE OF PROPER DRAFT

Draft  is  the  force  which  moves  air  from  the  appliance  up  through  the 

chimney. The amount of draft in your chimney depends on the length of 

the chimney, local geography, nearby obstructions and other factors. Too 

much draft may cause excessive temperatures in the appliance and may 

damage the catalytic  combustor (if  equipped).  Inadequate draft may 

cause backpuffing into the room and ‘plugging’ of the chimney or the 

catalyst (if equipped). Inadequate draft will cause the appliance to leak 

smoke into the room through appliance and chimney connector joints. An 

uncontrollable burn or excessive temperature indicates excessive draft.

Содержание US1269E

Страница 1: ...roperly installed a house fire may result For your safety follow the installation instructions Never use make shift compromises during the installation of this heater Contact local building or fire of...

Страница 2: ...his heater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for woodheaters sold after May 15 2020 Under specific EPA test conditions burning Douglas Fir dimensional lumb...

Страница 3: ...Using Coal and Wood Stoves Safely NFPA No HS 10 1978 The address of the NFPA is Batterymarch Park MA 02269 For more information on a Canadian Installation obtainacopyofCAN CSA B365 M91Installation Cod...

Страница 4: ...fety Glasses Hearth Gloves Pencil 6 Folding Ruler or Tape Measure Tin Snips Drill 1 8 dia Drill Bit Adjustable Wrench 2 philips screw driver Chimney Connector 1 2 Sheet Metal Screws Chimney Furnace Ce...

Страница 5: ...he front legs to the hearth with two 2 1 4 20 x 1 3 4 screws two 2 washers and two 2 1 4 20 jam nuts NOTE Only one leg is equipped with a handle bracket This bracketed leg is designed to be installed...

Страница 6: ...ry chimney properly lined or a UL ULC Listed chimney Ensure that the fixed flue baffle that is provided is installed in the flue collar This baffle is intended to be in a fixed location for optimal co...

Страница 7: ...ior portion of the chimney RULES FOR CONNECTOR PIPE INSTALLATION 1 The crimped end of the pipe must be installed toward the heater The pipe should slide into the flue collar The pipe should be firmly...

Страница 8: ...om combustible materials by a minimum of 6 glass fiber insulation The opening in the combustible wall shall be covered and the thimble supported with sheet steel supports which are at least 24 gauge 0...

Страница 9: ...ctions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN...

Страница 10: ...garbage 2 Lawn clippings or yard waste 3 Materials containing rubber including tires 4 Materials containing plastic 5 Waste petroleum products paints or paint thinners or asphalt products 6 Materials...

Страница 11: ...d is damp If the wood hisses and water or vapor escapes at the ends of the piece the wood is soaked or freshly cut Do not use this wood in the stove Large amounts of creosote could be deposited in the...

Страница 12: ...urn rates are not always the best heating burn rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out...

Страница 13: ...the heated flue liner ASH REMOVAL AND DISPOSAL Whenever ashes get 3 to 4 inches deep in the firebox or ash pan and when the fire has burned down and cooled remove excess ashes Leave an ash bed approxi...

Страница 14: ...r having completed this operation AIR TUBES The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the highest efficiency Any damage or deterioration o...

Страница 15: ...n Top 1 3 88033 3 8 Rope Joint Top 1 4 88329 Baffle Board 1 5 893217 Tube Weldment 1 6 86961 1 Side Secondary Tube 1 7 86962 2 Side Secondary Tube 1 8 40299 Main Back 1 9 40892 Firebox Side 2 10 40897...

Страница 16: ...16 Notes...

Страница 17: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Страница 18: ...EFFICACE ET FIABLE DE L APPAREIL DE CHAUFFAGE ET VOUS PERMETTRA DE COMMANDER CORRECTEMENT DES PI CES DE RECHANGE VEUILLEZ CONSERVER CE GUIDE DANS UN ENDROIT S R DES FINS DE R F RENCE LORSQUE VOUS NOUS...

Страница 19: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 20: ...d flecteur 1 5 893217 tube soud 1 6 86961 Tube secondaire 1 c t 1 7 86962 Tube secondaire 2 c t s 1 8 40299 dos principal 1 9 40892 c t bo te feu 2 10 40897 fond principal 1 11 40817 jambe 4 12 89975...

Страница 21: ...SECONDAIRES Les conduits d air secondaires doivent tre nettoy s avec une brosse m tallique Si des d bris demeurent dans les trous frappez l g rement avec un b ton de bois pour les d loger CONDUITS D...

Страница 22: ...ions de fum e et du monoxyde de carbone CO Le CO est un gaz poison lorsque l exposition se fait des concentrations lev es pour une p riode de temps prolong e Bien que les syst mes de combustion modern...

Страница 23: ...la chemin e et il consume galement moins de bois CONSEILS DE FONCTIONNEMENT POUR UNE COMBUSTION DE QUALIT EFFICACE ET PROPRE Utilisez de plus petits morceaux de bois pendant l allumage et un taux de...

Страница 24: ...de cr osote pourraient se d poser dans votre chemin e cr ant les conditions pour un potentiel feu de chemin e AVERTISSEMENT DE SABOTAGE Ce chauffage au bois a un taux de combustion minimum r gl la fab...

Страница 25: ...ction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de papier carton sciure de bois cire et substances similaires aux fins de d marrer le feu dans un chauffage au bois...

Страница 26: ...dans la maison ou une accumulation excessive d eau ou de cr osote dans la chemin e est un avertissement que la chemin e ne fonctionne pas correctement Corrigez le probl me avant d utiliser le chauffa...

Страница 27: ...A CHEMIN E ET LA MA ONNERIE LE SUPPORTS DE T LE D ACIER ET LES MAT RIAUX COMBUSTIBLES DE 5 CM 2 PO LONGUEUR DE CHEMIN E GALIT AVEC LE CONDUIT DE FUM E INT RIEUR CIMENT R FRACTAIRE NON SOLUBLE CHEMIN E...

Страница 28: ...s 24 0 024 po d paisseur Les supports de t le d acier doivent tre solidement fix s aux surfaces murales sur tous les c t s et tre d une taille suffisante pour s ajuster et maintenir la section de chem...

Страница 29: ...eut provoquer un retour de souffle dans la pi ce et un colmatage de la chemin e ou du catalyseur le cas ch ant Un tirage inad quat entra nera une fuite de fum e dans la pi ce par les joints de l appar...

Страница 30: ...chemin e commence dans le plafond vous aurez besoin d une longueur de tuyau de 15 cm 6 po pour l atteindre Le haut de la chemin e doit tre au moins 91 cm 3 pi au dessus du toit et d passer d au moins...

Страница 31: ...2 Encore une fois v rifiez les illustrations suivantes et assurez vous d avoir les d gagements montr s du chauffage et du tuyau de raccordement par rapport aux surfaces combustibles Si vous avez de la...

Страница 32: ...20 6 Fixez les pieds avant au foyer avec deux 2 vis 1 4 20 x 1 3 4 deux 2 rondelles et deux 2 contre crous 1 4 20 REMARQUE Un seul pied est quip d un support de poign e Ce pied support est con u pour...

Страница 33: ...assemblage AVIS United States Stove Company n accorde aucune garantie implicite ou d clar e pour l installation ou l entretien de votre po le bois et n assume aucune responsabilit quant tous dommages...

Страница 34: ...artir de l ext rieur de la maison dans la pi ce o le chauffage est situ Si la prise n est pas dans la m me pi ce l air doit avoir un acc s libre dans la pi ce 8 Pour viter les blessures ne laissez per...

Страница 35: ...tuyau de raccordement 15 cm 6 po Type de tuyau de raccordement Mur simple standard Noir ou acier bleui 650 C 2100 F Hauteur minimum de la chemin e 3 7 m 12 pi Longueur maximum de b che 483 mm 19 po l...

Страница 36: ...les appareils de chauffage combustion simple Ce po le bois combustion unique n est pas approuv pour utilisation avec un registre de combustion United States Stove Company 227 Industrial Park Road Sou...

Отзывы: